background image

Decommissioning

42

Operating and installation instructions 0020248975_01

9

 

>

Do not combine new and used batteries.

 

>

Insert the batteries, making sure that 
the poles are the right way round. 

 

>

Remove the dead batteries from the 
product and dispose of them correctly.

 

>

Remove the batteries if you intend to 
store the product and not use it for an 
extended period and/or to scrap it.

 

>

Do not short-circuit the connection con-
tacts in the product’s battery compart-
ment.

9 Decommissioning

9.1 Decommissioning 

the 

product

1.  Delete the product in the 

VRC 700

 app.

2.  Remove the product from the wall.
3.  Remove the batteries.

Summary of Contents for VR 51

Page 1: ...ing and installation instructions GB IE Room thermostat VR 51 Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaill...

Page 2: ...9 3 System and product description 10 3 1 Component of the ambiSENSE system 10 3 2 Design of the product 11 3 3 Display 12 3 4 Radio operation 14 3 5 Flashing sequence of the signal LED 15 3 6 Duty c...

Page 3: ...k 32 7 Troubleshooting 32 7 1 Detecting and rectifying faults 32 7 2 Command not confirmed 33 7 3 Resetting to factory setting 34 8 Care and maintenance 37 8 1 Caring for the product 37 8 2 Changing b...

Page 4: ...arnings The action related warnings are classified in accordance with the severity of the pos sible danger using the following warning signs and signal words Warning symbols and signal words a Danger...

Page 5: ...y arise You can use the room thermostat for the time controlled regulation of individual rooms Intended use includes the following observance of accompanying operating installation and servicing instr...

Page 6: ...ment shall be considered improper use Any direct commercial or industrial use is also deemed to be improper Caution Improper use of any kind is prohibited 1 3 General safety information 1 3 1 Danger c...

Page 7: ...are provided in these oper ating instructions 1 3 2 Risk of material damage caused by frost Do not install the product in rooms prone to frost 1 3 3 Danger caused by a malfunction Install the product...

Page 8: ...electronics may be damaged if you install the product in an unsuitable envi ronment Only install the product in dry dust free rooms Ensure that the product is not exposed to constant solar or heat ir...

Page 9: ...g other applicable documents You must observe all the operating and installation instructions included with the system components 2 2 Storing documents Keep this manual and all other applica ble docum...

Page 10: ...e solution can be configured via the VRC 700 app using a smartphone You can use the room thermostat with air humidity sensor for the time controlled regulation of the room temperature via the VRC 700...

Page 11: ...n cycles meaning that the room temperature can be regulated even more precisely The installation takes place by screwing in or sticking the mounting plate and fasten ing in the clip on frame that is s...

Page 12: ...ions 0020248975_01 3 1 Mounting plate 2 Clip on frame 3 Setting wheel 4 System button 5 Display 6 Room thermostat 3 3 Display i Note The background lighting for the display is switched off in standby...

Page 13: ...020248975_01 13 3 SET MANU BOOST 9 8 7 6 1 2 3 5 4 1 Operation lock active 2 Unit for the numeric display 3 Automatic decrease active 4 Radio data transmission 5 Low battery charge 6 Boost mode active...

Page 14: ...fore not be ruled out Interfer ences may for example be caused by switching operations electric motors or defective electrical units The range inside buildings may differ con siderably from the range...

Page 15: ...vity Brief period of flashing orange Radio trans mission transmission attempt or configuration data is trans ferred Wait until the transmission has ended 1 x long period of lighting up green Process c...

Page 16: ...nter the dig its of the unit number to confirm Brief period of lighting up orange after a green or red reception notification Batteries flat Replace the batteries 3 x long period of flashing red Produ...

Page 17: ...red Dura tion Up to 12 hours This does not affect how the product works during this time 3 6 Duty cycle limit The duty cycle limit describes a legally regulated limit on the transmission time of units...

Page 18: ...ases e g during start up or the new installation of a system increased and radio intensive pair ing processes may mean that this limit is not reached If the duty cycle limit is exceeded the signal LED...

Page 19: ...the data plate The manufacturer hereby declares that the type of radio equipment that is described in these instructions complies with Direc tive 2014 53 EU The complete text for the EU Declaration of...

Page 20: ...3 Micro AAA batteries 2 5 mm rawl plug 3 x 30 mm cross head screws 2 Double sided adhesive strips 1 Unit number sticker 1 Operating and installation instructions 4 Integration into the ambiSENSE syste...

Page 21: ...t via the VRC 700 app as follows Open the VRC 700 app on the smart phone Select Settings on the bottom right Select ambiSENSE Select Add individual room compo nent Follow the installation assistant Wh...

Page 22: ...e app to confirm or use the smart phone to scan the QR code i Note You can find the unit number and the QR code on the enclosed sticker and in the product s battery com partment Wait until the pairing...

Page 23: ...t free room Do not install the room thermostat Close to heat sources such as radiators chimney walls television sets direct sunlight Above a cooker from which vapours and grease are released On cold w...

Page 24: ...t into an existing switch series To install it in the clip on frame you can use either the supplied double sided adhesive strips or the supplied screws to secure the room thermostat to the wall Instal...

Page 25: ...rating and installation instructions 0020248975_01 25 5 B A 1 2 Secure the adhesive strips 1 to the rear of the mounting plate 2 in the markings provided for that purpose Ensure that you can read the...

Page 26: ...248975_01 5 the rear and that the clips for the mounting plate can click into the open ings on the room thermostat Remove the plastic film from the adhe sive strips Press the assembled room thermostat...

Page 27: ...Set up Operating and installation instructions 0020248975_01 27 5 Screw mounting 2 1 3 B A Select a suitable installation site in the room...

Page 28: ...site to each other i Note Ensure that the arrow on the front of the mounting plate is pointing upwards If required use the holes 2 for the installation on a flush mounted box Drill the pre marked hol...

Page 29: ...cturers or you can integrate it into a multiframe The room thermostat fits into frames from the following manufacturers Berker S 1 B 1 B 3 B 7 glass ELSO Joy GIRA System 55 Standard 55 E2 E22 Event Es...

Page 30: ...p is active Manual mode You can set the temperature on the product or by using the VRC 700 app The temperature setting is retained until the next time a manual change is implemented Press and hold the...

Page 31: ...re should apply can be individually defined here In manual mode the temperature is retained until the next time a manual change is implemented Turn the setting wheel clockwise or anti clockwise to man...

Page 32: ...acti vate the product s operation lock 7 Troubleshooting 7 1 Detecting and rectifying faults Conditions The room temperature does not reach the set temperature Check whether the radiator thermostats o...

Page 33: ...ng wheel briefly once Check whether the Low battery sym bol is shown in the display Check that the batteries for the room thermostat have been correctly inserted in the battery compartment 7 2 Command...

Page 34: ...allation instructions 0020248975_01 7 Transceiver cannot implement the com mand load failure mechanical block age etc Defective transceiver 7 3 Resetting to factory setting i Note All settings will be...

Page 35: ...Troubleshooting Operating and installation instructions 0020248975_01 35 7 B 2 Re insert the batteries in accordance with the polarity markings and at the same time press and hold the system...

Page 36: ...ur seconds until the signal LED starts to rapidly flash in orange 3 Release the system button 4 Press the system button again for four seconds until the signal LED lights up green 5 Release the system...

Page 37: ...Care and maintenance 8 1 Caring for the product b Caution Risk of material damage caused by unsuitable cleaning agents Do not use sprays scouring agents detergents solvents or cleaning agents that co...

Page 38: ...8975_01 8 8 2 Changing batteries 1 1 Remove the product from the mounting plate 2 Always change all the batteries 1 at the same time Battery type LR03 Micro AAA 3 Do not use rechargeable batteries 4 I...

Page 39: ...ce 5 After inserting the batteries observe the flashing sequence of the signal LED Self test successful Signal LED lights up orange first and then green 6 Push the product in the clip on frame back on...

Page 40: ...battery type when replacing batteries Dispose of used batteries in accordance with the instruc tions in this manual 8 2 2 Leaking batteries a Danger Risk of chemical burns caused by leaking batteries...

Page 41: ...cal burns e g wear protective gloves 8 2 3 Batteries Note the battery type as described in these instructions see section Data plate Remove and insert batteries as described in these instructions see...

Page 42: ...batteries from the product and dispose of them correctly Remove the batteries if you intend to store the product and not use it for an extended period and or to scrap it Do not short circuit the conne...

Page 43: ...d hand in the product to a collec tion centre for old electrical or elec tronic appliances If the product contains batteries that are labelled with this mark these bat teries may contain substances th...

Page 44: ...e 2x 1 5 V LR03 Micro AAA Current consumption 50 mA Battery life 2 years IP rating IP 20 Degree of contamina tion 2 Maximum permitted environmental temperature 0 35 C Height 86 mm 3 39 in Width 86 mm...

Page 45: ...ing and installation instructions 0020248975_01 45 11 Parameter Value Maximum transmission power 25 mW Receiver category SRD category 2 Range outdoors 250 m 820 ft 3 in Duty cycle 1 per h 10 per h Mod...

Page 46: ......

Page 47: ......

Page 48: ...opyright and may be reproduced or distributed only with the manufacturer s written consent We reserve the right to make technical changes Supplier Vaillant Ltd Nottingham Road Belper Derbyshire DE56 1...

Reviews: