Note:
Heat up time based on a primary flow rate of
9 l/min at 80 °C.
Temperature rise is from 15 °C to 65 °C.
2 Technical data
uniSTOR GB
4
VIH GB 125 S VIH GB 155 S VIH GB 180 S VIH GB 210 S VIH GB 260 S VIH GB 310 S
Unit
Size
125
155
180
210
260
310
litres
Maximum water supply pressure
10
bar
Operating pressure
3.5
bar
Pressure reducing valve
3.5
bar
Expansion relief valve
6.0
bar
Expansion vessel charge pressure
4.0
bar
T/P valve
95 / 7.0
°C/bar
Net weight
28
30
33
39
44
49
kg
Weight (full)
145
175
205
245
310
340
kg
Height
969
1179
1339
1499
1789
2109
mm
Cylinder connections:
Cold mains inlet
22 mm compression
DHW outlet
22 mm compression
Balanced pressure cold water outlet
22 mm compression
Secondary return
G 3/4
Primary flow
22 mm compression
Primary return
22 mm compression
Electrical connections:
3 kW Immersion heater
(according ENBS 60335)
230/240 V, 50 Hz
Length of Immersion heater
430
mm
Two port valve
230/240 V, 50 Hz
Cylinder thermostat
230/240 V, 50 Hz
Coil Specifications:
Heat loss
1.4
1.7
1.8
1.9
2.1
2.4
kW/24h
Heat up time
21
23
24
27
35
47
min
Recovery
18
18.5
19
22
30
42
min
2 Technical data