17
aroTHERM plus with DHW Cylinder, Decoupler, 1 Radiator Zone, 1 Underfloor Heating
Zone (3rd Party)
Setting
Value
Installation
Adaptive heat. curve Deactivated
Hybrid manager
Bivalence pt.
Heating bivalence point
-20
o
DHW bivalence point: -20
o
Alternative point Off
ESCO
Heating off
Back-up boiler Off
Conf. ext. input Open, deactiv.
Basic system diagram configuration
Basic system diagram code
10
FM3 configuration:
3
FM3 MO
Not working
HP control module configuration
MO 2 Circ. pump
Circuit 1
Circuit type
Heating
OT switch-off threshold 30
o
Heat curve
**Site specific
Min. target flow temp.
15
o
Max. target flow temp.
45
o
Set-back mode Normal
Room temp. mod. Expanded
Circuit 2
Circuit type
Heating
OT switch-off threshold 30
o
Heat curve
**Site specific
Min. target flow temp.
15
o
Max. target flow temp.
45
o
Set-back mode Eco
Room temp. mod. Inactive
Zone 1
Zone activated Yes
Zone assignment
Control
Zone 2
Zone activated Yes
Zone assignment No assignmt
Domestic hot water
Cylinder Active
Anti-legio. day
**User pref.
Anti-legio. time
**User pref.
Cylinder charging offset
15 K
Cyl. charg. anti-cycl. time
5 min
Summary of Contents for UK aroTHERM plus
Page 119: ...119...