11
aroTHERM plus with DHW Cylinder, Decoupler, 1 Underfloor Heating Zone (3rd Party)
Setting
Value
Installation
Adapt. heat curve: Deactivated
Hybrid manager
Bivalence pt
Heating bivalence point
-20
o
DHW bivalence point -20
o
Alternative point Off
ESCO HP off,
Heating off
Back-up boiler Off
Basic system diagram configuration
Basic system diagram code
10
HP control module configuration
MO 2 Circulation
pump
Circuit 1
Circuit type
Heating
OT switch-off threshold
30
o
Heat curve
**Site specific
Auto Off mode
15
o
Max. target flow
temperature
45
o
Set-back mode Eco
Room temp. mod. Inactive
Zone 1
Zone activated Yes
Zone assignment
No assignmt.
Domestic hot water
Cylinder Active
Anti-legio. day
** User pref.
Anti-legio. time
**User pref
Cylinder charging offset
15 K
Cyl. charg. anti-cycl. time
5 min
Summary of Contents for UK aroTHERM plus
Page 119: ...119...