3 Product description
10
Installation and maintenance instructions geoTHERM 0020250180_00
3.2.2
Functionality
3.2.2.1 Heat pump
10
9
1
2
3
6
5
7
4
8
1
Heating pump
2
Condenser
3
Filter element
4
Electronic expansion
valve
5
Printed circuit board
6
Evaporator
7
Brine pump
8
Brine mixer
9
Rotary compressor
10
Intermediate heat ex-
changer
The product is a brine-to-water heat pump and uses geo-
thermal energy as a heat source.
The heat pump consists of the following separate circuits
which are coupled with one another by means of heat ex-
changers. These circuits are:
–
The brine circuit, which extracts the thermal energy from
the ground or the ground water and transfers this to the
refrigeration circuit
–
The refrigerant circuit, which is used to bring the thermal
energy from the ground to a usable, higher temperature
level and deliver it to the heating circuit
–
The heating circuit, which is used to heat up the living
rooms
3.3
Information on the data plate
The data plate is mounted on the underside of the product.
Information on the data
plate
Meaning
Serial no.
Unique unit identification number
Measuring voltage of the com-
pressor, pumps and controls
P max
Maximum rated power
I max
Maximum in-rush current
Refrigerant type, fill quantity,
permissible rated overpressure
COP B0/W35
Output figure (coefficient of per-
formance) at a brine temperature
of 0 °C and heating flow temper-
ature of 35 °C
COP B0/W55
Coefficient of performance at a
brine temperature of 0 °C and
heating flow temperature of 55
°C
Information on the data
plate
Meaning
B0/W35
Heating output at a brine tem-
perature of 0 °C and heating flow
temperature of 35 °C
B0/W55
Heating output at a brine tem-
perature of °C and heating flow
temperature of 55 °C
Volt
Mains voltage
Hz
Mains frequency
W
Power consumption
IP
Protection class
Information on disposal
Reading the operating and
installation instructions
3.4
Explanation of product stickers
Symbol on the sticker
Meaning
Heating flow connection
Heating return connection
Connection from the heat
source to the heat pump (hot
brine)
Connection from the heat
pump to the heat source
(cold brine)
Brine heat source
3.5
CE label
The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.
The declaration of conformity can be viewed at the manufac-