4 Set-up
8
Installation and maintenance instructions ecoTEC plus 0020261188_00
4.3
Dimensions
108
100
A
100
100
173
440
125
78
720
220
235
120
120
85,5
133,8
29,5
825
6
1
2
3
9
10
4
5
7
8
1
Condensate siphon
2
Heating flow connection
3
Gas connection
4
Heating return connec-
tion
5
Drain for the rainwater
collecting device
6
Position of the holes for
the flue system
7
Retainer for securing
the product
8
Gas pressure connec-
tion
9
Connection for the
air/flue pipe
10
Drain for the dynamic
air separation system
Dimension A
VC 406/5-5 (E-DE)
405 mm
VC 406/5-5 (LL-DE)
405 mm
VC 476/5-5 (E-DE)
405 mm
VC 476/5-5 (LL-DE)
405 mm
VC 636/5-5 (E-DE)
473 mm
VC 636/5-5 (LL-DE)
473 mm
4.4
Minimum clearances
C
C
A
B
D
▶
When using the accessories, observe the minimum clear-
ances/installation clearances.
Minimum clearances
A
B
C
D
≥
275 mm
≥
180 mm
≥
5 mm
≥
500 mm
–
Optimum dimension
(B)
:
≈
250 mm
–
Optimum dimension
(C)
:
≈
50 mm
–
Dimension
(D)
: The clearance in front of the product
to facilitate easy access for maintenance work can
be reduced to 5 mm if there is a door in front of the
product
4.5
Clearance from combustible components
It is not necessary to maintain a clearance between the
product and components made of combustible materials that
go beyond the minimum clearances.
4.6
Using the mounting template
▶
Use the mounting template to ascertain the locations at
which you need to drill holes and make breakthroughs.