4 Set-up
8
Installation and maintenance instructions ecoTEC exclusive 0020186710_06
4.3
Dimensions
620
20
720
A
B
125
180
130
440
80
188
160
100
100
55
55
13
1
3
4
5
3
5
12
4
6
7
8
9
2
10
11
1
Flue pipe wall duct
2
Product bracket
3
Heating flow
4
Gas connection
5
Heating return
6
Connection for the
heating expansion relief
valve drain line
7
Condensate discharge
connection
8
Condensate siphon
9
Cylinder return
10
Circulation section
11
Cylinder primary pipe-
work
12
R1 tundish/condensate
siphon connection
13
Flue pipe connection
Consult the installation template that is supplied to find the
dimension A.
The product's installation depth B can be found in the tech-
nical data in the appendix.
4.4
Minimum clearances
B
A
C
C
D
Minimum clearance
A
165 mm: Air/flue pipe, 60/100 mm diameter
275 mm: Air/flue pipe, 80/125 mm diameter
B
180 mm; optimum approx. 250 mm
C
5 mm; optimum approx. 50 mm
D
500 mm in front of the heat generator to enable
easy access for maintenance work (may be
provided by an opening door).
4.5
Using the installation template
▶
Use the installation template to ascertain the locations at
which you need to drill holes and make perforations.