Supplied By www.heating spares.co Tel. 0161 620 6677
Boiler Specification 3
Instructions for Installation and Servicing turboMAX plus and thermoCOMPACT R1
7
thermoCOMPACT thermoCOMPACT thermoCOMPACT thermoCOMPACT thermoCOMPACT
615/2 E
620/2 E
624/2 E
628/2 E
637 E
Units
(VU GB 152/2-5) (VU GB 202/2-5) (VU GB 242/2-5) (VU GB 282/2-5) (VU GB 362-5)
Maximum CH heat input
16.5
22.0
26.7
31.1
40.5
kW
(net)
(56,100)
(74,800)
(91,200)
(106,200)
(138,300)
(Btu/h)
CH heat output range
6.5. - 15
7.7 - 20
8.9 - 24
10.4 - 28
10.5 - 36.9
kW
(80/60 °C)
(22,300-51,200)
(26,300 - 68,300) (30,400 - 81,900)
(35,500 - 95,500) (35,800 - 126,000) (Btu/h)
SEDBUK Band
D
D
D
D
D
SAP Seasonal Efficiency
79.0
79.7
79.7
79.8
79.8
%
Inlet gas working pressure
required (natural gas)
20
20
20
20
20
mbar
Gas supply (G20)
37.8
37.8
37.8
37.8
37.8
MJ/m3
Gross CV (s.t.)
Gas burner pressure
9.9
9.0
9.8
10.5
12.0
mbar
max. rate
Gas burner pressure
2.2
1.5
1.9
1.8
1.2
mbar
ignition rate
CH temperature
35 - 82
35 - 82
35 - 82
35 - 82
35 - 82
°C
flow range
Minimum CH water flow
(for 20 °C rise)
650
860
1032
1203
1587
l/h
Pump pressure available
0.25 (25)
0.25 (25)
0.25 (25)
0.25 (25)
0.17 (17)
bar
(KPa)
Expansion vessel
pre-charge pressure
0.75
0.75
0.75
0.75
0.75
bar
Maximum CH
3
3
3
3
3
bar
system pressure
Weight
38
39
41
43
45
kg
Primary water content
2.0
2.0
2.0
2.0
2.2
l
Electrical supply
230/50
230/50
230/50
230/50
230/50
V~/Hz
External fuse
3
3
3
3
3
A
Power input
150
150
150
150
130
W
Case height
800
800
800
800
800
mm
Case width
440
440
440
440
440
mm
Case depth
338
338
338
338
338
mm