Supplied By www.heating spares.co Tel. 0161 620 6677
7 Gas supply adjustments (Commissioning Part II)
Instructions for Installation and Servicing turboMAX plus and thermoCOMPACT R1
32
Gas Rate thermoCOMPACT 615/2 E
Output[kW]
Gas type
6.5
8.0
10.0
12.0
14.0
15.0
Natural gas 2H
Gas Rate
1)
[m
3
/h]
Main burner jet mark
2)
for G20
0.8
1.0
1.3
1.4
1.7
1.7
7 / 120
Gas Rate thermoCOMPACT 620/2 E
Output[kW]
Gas type
7.7
8.0
10.0
12.0
14.0
16.0
18.0
20.0
Natural gas 2H
Gas Rate
1)
[m
3
/h]
Main burner jet mark
2)
per G20
0.9
1.0
1.2
1.4
1.7
1.9
2.1
2.3
7 / 120
Gas Rate thermoCOMPACT 624/2 E, turboMAX plus 824/2 E
Output[kW]
Gas type
8.9
10.0
12.0
14.0
16.0
18.0
20.0 22.0 24.0
Natural gas 2H
Gas Rate
1)
[m
3
/h]
Main burner jet mark
2)
for G20
1.1
1.2
1.4
1.7
1.9
2.1
2.4
2.6
2.8
7 / 120
Gas Rate thermoCOMPACT 628/2 E, turboMAX plus 828/2 E
Output[kW]
Gas types
10.4 12.0
14.0
16.0 18.0
20.0 22.0
24.0
26.0
28.0
Natural gas 2H
Gas Rate
1)
[m
3
/h]
Main burner jet mark
2)
per G20
1.3
1.5
1.7
1.9
2.1
2.4
2.6
2.8
3.1
3.3
7 / 120
Gas Rate thermoCOMPACT 637E, turboMAX plus 837 E
Output[kW]
Gas type
10.5 12.0
16.0
18.0 20.0 24.0 28.0
30.0
33.0
36.9
Natural gas 2H
Gas Rate
1)
[m
3
/h]
Main burner jet mark
2)
per G20
1.3
1.5
1.9
2.2
2.4
2.8
3.3
3.5
3.9
4.3
7 / 120
Burner Pressure thermoCOMPACT 637, turboMAX plus 837 E
Output[kW]
Gas type
Ignition rate 10.5 12.0 16.0 18.0 20.0 24.0 28.0 30.0 33.0 36.9
Natural gas 2H
Burner pressure
1)
[mbar]
Main burner jet mark
2)
for G20
1.2
1.2
1.5
2.5
3.1
3.8
5.3
7.1
8.1
9.7
12.0
7 / 120
Setting-up program: P.11
mid. setting point pressure: 5.3 mbar
LPG 3 B/P
Burner pressure
1)
[mbar]
Main burner jet mark
2)
for G30
2.8
2.8
3.5
5.9
7.3
8.9
12.6
16.8
19.1
22.9 28.2
7 / 072
for G31
3.5
3.5
4.4
7.3
9.1
11.1
15.6 20.8
23.7
28.3 34.9
Setting-up program: P.13
mid. setting point pressure: 15.3 mbar
Table 7.1: Burner pressure
Table 7.2: Gas flow rate
1) 15 °C, 1013mbar, dry
2) The nozzles are stamped with the mark shown in this table.
The marking corresponds to the nozzle hole diameter multiplied by 100