Supplied By www.heating spares.co Tel. 0161 620 6677
9 Servicing
• Turn off the boiler CH service valves.
• Turn off the cold water inlet service valve.
• Release the three clamps (1), remove the combustion
chamber cover (2).
9.2.1 For thermoCOMPACT 615, 637 and turboMAX
plus 837
• Remove the flue gas connector (2a) on the fan.
• Remove the retaining spring (3).
• 115
5 k
kW
W:: Pull the three cables (4) and two tubes (5) from
the fan assembly.
• 3
37
7 k
kW
W:: Remove both plugs (not illustrated) and both
hoses (5) from the fan.
• Remove the fan assembly (6).
• Remove the four screws (7) and detach the front cover
panel from the combustion chamber (8).
• Check the burner (9) and heat exchanger fins (10) and
remove any loose deposits with a soft brush.
9.2.2 For thermoCOMPACT 620, 624, 628,
turboMAX pro 24, 28 and turboMAX plus 824,
828
• Pull the three cables (4) and two tubes (5) from the
fan assembly.
• Remove the fan assembly (6a, 6b, 6c).
• Remove the four screws (7) and detach the front cover
panel from the combustion chamber (8).
• Check the burner (9) and heat exchanger fins (10) and
remove any loose deposits with a soft brush.
• Reassemble in reverse order.
Check central heating expansion vessel.
Note!
It is not necessary to carry out this check every
year – a check every three years should be
sufficient.
• Release the system water pressure from the boiler.
• Remove valve cap from expansion vessel charge point.
• Check that the internal charge pressure of expansion
vessel is between 0.7 - 0.9 bar. If pressure is lower
than this the vessel should be re-pressurised using an
air pump.
• Refit valve cap.
• Open central heating service valves and re-pressurise
the boiler and heating system if necessary.
• Open the gas service valve.
• Turn on the mains power supply.
• Operate the boiler and carry out soundness, safety
and function checks.
• Complete the service interval record section in the log
book and leave with the user.
Instructions for
36
Fig. 9.1a Cleaning the burner and primary heat exchanger
(thermoCOMPACT 615, 637 and turboMAX plus 837)
Fig. 9.1b Cleaning the burner and primary heat exchanger
thermoCOMPACT 620, 624, 628, turboMAX pro 24,
28 and turboMAX plus 824, 828
6a
6b
7
9
10
8
2
1
5
5
4
6c
6
4
4
4
5
5
7
9
10
8
1
2
3
2a