Gas supply adjustments (Commissioning Part II) 7
Instructions for Installation and Servicing turboMAX plus and thermoCOMPACT R1
31
Burner Pressure and gas rate
Burner Pressure thermoCOMPACT 615/2 E
Output[kW]
Gas type
Ignition rate
6.5
8.0
10.0
12.0
14.0
15.0
Natural gas 2H
Burner pressure
1)
[mbar]
Main burner jet mark
2)
for G20
2.2
2.2
3.2
4.7
6.6
8.7
9.9
7 / 120
LPG 3 B/P
Burner pressure
1)
[mbar]
Main burner jet mark
2)
for G30
4.1
4.1
6.2
9.6
13.6
18.1
20.6
7 / 072
for G31
5.8
5.8
8.7
13.3
18.7
24.9
28.3
Burner Pressure thermoCOMPACT 620/2 E
Output[kW]
Gas type
Ignition rate
7.7
8.0
10.0
12.0
14.0 16.0
18.0
20.0
Natural gas 2H
Burner pressure
1)
[mbar]
Main burner jet mark
2)
for G20
1.5
1.5
1.6
2.4
3.4
4.6
5.9
7.4
9.0
7 / 120
LPG 3 B/P
Burner pressure
1)
[mbar]
Main burner jet mark
2)
for G30
2.0
2.0
3.2
5.0
7.3
9.9
12.8
16.1
19.7
7 / 072
for G31
4.3
4.3
4.5
71
10.1
13.7
17.6
22.0
26.9
Burner Pressure thermoCOMPACT 624/2 E, turboMAX plus 824/2 E
Output[kW]
Gas type
Ignition rate 8.9 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0
Natural gas 2H
Burner pressure
1)
[mbar]
Main burner jet mark
2)
for G20
1.9
1.9
2.1
2.9
3.7
4.7
5.8
6.7
8.4
9.8
7 / 120
LPG 3 B/P
Burner pressure
1)
[mbar]
Main burner jet mark
2)
for G30
3.9
3.9
4.8
6.8
9.0
11.6
14.3
17.4
20.6
24.1
7 / 072
for G31
5.2
5.2
6.4
8.8
11.6
14.8 18.3
22.1
26.2
30.6
Burner Pressure thermoCOMPACT 628/2 E, turboMAX plus 828/2 E
Output[kW]
Gas type
Ignition rate 10.4 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 28.0
Natural gas 2H
Burner pressure
1)
[mbar]
Main burner jet mark
2)
for G20
1.8
1.8
2.3
3.0
3.9
4.8
5.8
6.8
8.0
9.2
10.5
7 / 120
LPG 3 B/P
Burner pressure
1)
[mbar]
Main burner jet mark
2)
for G30
4.1
4.1
5.3
7.1
9.0
11.2
13.5
16.1
18.8
21.7
24.8
7 / 072
for G31
5.5
5.5
7.1
9.5
12.1
15.0 18.1
21.6
25.2 29.1
33.2
Table 7.1: Burner pressure
1) 15 °C, 1013mbar, dry
2) The nozzles are stamped with the mark shown in this table. The
marking corresponds to the nozzle hole diameter multiplied by 100