Appendix
24
Installation and maintenance instructions atmoMAG 0020273765_00
Technical data
–
Power/load
MAG mini 114/1 I(P-
INT)
Domestic hot water volume at the
"hot" temperature selector posi-
tion
2.6 … 5.5 l/min
Domestic hot water volume at the
"warm" temperature selector posi-
tion
5.4 … 11.0 l/min
Max. heat input (in relation to the
net calorific value H
i
)
21.7 kW
Min. heat input (Q
min.
)
7.6 kW
Max. heat output (P
max.
)
18.1 kW
Min. heat output (P
min.
)
6.4 kW
Control range
6.4 … 18.1 kW
Max. permissible water pressure
P
w max.
1.3 MPa
(13.0 bar)
Min. permissible water pressure
P
w min.
when the temperature se-
lector is positioned at "warm"
0.31 bar
(31,000 Pa)
Min. permissible water pressure
P
w min.
when the temperature se-
lector is positioned at "hot"
0.16 bar
(16,000 Pa)
Flue gas temperature at max. heat
output
200
℃
Flue gas temperature at min. heat
output
105
℃
Min. chimney draught
1.5 Pa
Min. chimney draught when using
a thermal flue non-return flap
10.0 Pa
Technical data
–
Liquid gas G31
Applicability:
Germany
OR Austria
MAG mini 114/1 I(P-
INT)
Gas flow rate at max. heat output
1.69 kg/h
Gas connection pressure
4.25 … 5.75 kPa
(42.50
… 57.50 mbar)
Number of burner jets
24
Burner jet
0.5 mm
Burner pressure
31.7 mbar
(0.0317 bar)
Air requirement for combustion at
max. heat input
38.3 m
³
/h
Air requirement for combustion at
min. heat input
28.9 m
³
/h
CO
₂
content at max. heat output
7.3 %
CO
₂
content at min. heat output
3.3 %
Max. flue gas mass flow rate
4.13 g/s
Min. flue gas mass flow rate
1.1 g/s