9

Operating manual atmoCRAFT

 Caution!

Risk of damage!
The frost protection and monitoring systems 
are only active when the main switch of the 
appliance is in the "I" position and it is not 
disconnected from the mains power supply.

To ensure that these protection devices remain active, 
switch your boiler on and off using the controller (see 
the corresponding operating manual).
Section 4.9 describes how to take your gas boiler out 
of commission.

4.4 

Settings for hot water preparation

2

3

Fig. 4.6  Adjusting the storage tank temperature (only if a hot 

water storage tank is included)

For hot water preparation using an atmoCRAFT boiler, a 
hot water tank must be connected to the boiler.

Proceed as follows to adjust it:
•  Turn the rotary knob (

3

) to the desired temperature. In 

doing this:

Turning all the way to the left, frost protection 15 °C
Minimum set water temperature 

40 °C

Turning all the way to the right
Maximum set water temperature 

70 °C.

When setting the desired temperature, the value is 
shown on the display (

2

) of the DIA-System.

After approx. five seconds the display returns to 
standard mode (the current heating feed temperature).

 Note!

We recommend a setting of 60 °C for economic 
and hygienic reasons (e.g. Legionella).

 Caution!

Danger of calcium deposit build-up.
If your water hardness is more than 1.79 mol/m

3

 

(10 °dh), do not turn the knob (3) further than 
the middle position.

4.4.1  Drawing hot water

•  Open one of the hot water taps at one of the water 

draw-off positions (hand-wash basin, shower, bath 
etc.). The hot water is drawn off from the integrated 
hot water storage tank.

If the water in the tank falls below the set temperature, 
the appliance starts up automatically and reheats it. 
During the charging process of the storage tank the 
read-out in the display (

2

) flashes 

, see Figure 4.6.

When the storage tank temperature that you have set is 
achieved, the unit switches off automatically. The pump 
continues to run for a short while.

4.4.2 Switching off the storage tank operation mode

On the atmoCRAFT boilers with connected hot water 
storage tanks you can switch the storage tank charging 
system off, whilst continuing to operate the heating 
system.
•  To do this, turn the rotary knob (

3

) for setting the hot 

water temperature all the way to the left, see Figure 
4.6. The frost protection function for the storage tank 
remains active.

A storage tank temperature of 15 °C is shown in the 
display (

2

), for approx. 5 seconds.

Operation 4

GB

Summary of Contents for atmoCRAFT VK SERIES

Page 1: ...VK 654 9 1654 9 atmoCRAFT DE AT GB CZ SK HU PL HR SI SCG...

Page 2: ...For the owner VK 654 9 1654 9 Operating manual atmoCRAFT Gas heating boiler GB...

Page 3: ...by exceeding the temperature 13 4 8 5 Faults with the exhaust gas removal 13 4 8 6 Filling unit heating installation 14 4 9 Shut down 14 4 10 Frost protection 15 4 10 1 Frost protection function 15 4...

Page 4: ...4 Data badge The identification plate is included with the burner and should be mounted on the separation wall 2 Safety What to do in an emergency Danger If you smell gas risk of poisoning and explos...

Page 5: ...sufficiently heated Caution Risk of damage If there is a power cut or if the room temperature is set too low in individual rooms it cannot be ruled out that sections of the heating system are damaged...

Page 6: ...en by the heating engineer The desired heating and set back phases e g at night are automatically turned on and off using the integrated time programmes Weather compensators combined with thermostat v...

Page 7: ...0 C also lead to increased lime scale production Energy conscious use of water Energy conscious use of water can reduce your bills considerably For example taking a shower instead of a bath whereas ab...

Page 8: ...nk temperature in normal mode if a storage tank sensor is connected 6 button for moving backwards in the display for adjustment and troubleshooting by the engineer 7 Reset button for resetting certain...

Page 9: ...0 6 5 4 3 bar 1 Fig 4 4 Checking the filling pressure of the heating installation pressure gauge not included Check the filling pressure of the installation using the pressure gauge 1 not included For...

Page 10: ...ng feed temperature Note We recommend a setting of 60 C for economic and hygienic reasons e g Legionella Caution Danger of calcium deposit build up If your water hardness is more than 1 79 mol m3 10 d...

Page 11: ...m fitted to your heating system 4 5 2 Setting the flow temperature no controller connected 1 2 Fig 4 8 Feed temperature setting without heating controller If there is no external controller set the fl...

Page 12: ...tion of your boiler Press the i button 1 to activate the status displays The display 2 then shows the individual status codes e g S 4 for burner operation The table below explains the most important s...

Page 13: ...he heating system see Section 4 8 2 Is there an ignition problem see Section 4 8 3 Hot water operation no problem Heating does not start Is there a requirement for heating from the external controller...

Page 14: ...exceeding the temperature 1 2 Abb 4 14 Releasing after STB switch off Your boiler is equipped with a safety temperature limiter STB which automatically switches off the boiler if the temperature gets...

Page 15: ...However in exceptions the water quality might not be suitable for filling in the heating system heavily corrosive or extremely calciferous water In a case such as this you should please contact your a...

Page 16: ...he frost protection system cannot guarantee flow through the entire heating system 4 10 2 Frost protection by draining Another way to protect the heating system and the appliance from frost is to drai...

Page 17: ...ed as follows to perform the measurements Activate the chimney sweep mode by simultaneously pushing the buttons 6 and 7 on the DIA System The measurements should be taken at the earliest after 2 minut...

Reviews: