Operating manual atmoCRAFT

For alterations to the appliance or to its environment, 
you must refer to the suitably qualified heating engineer 
which is responsible for it.

 Caution!

Inappropriate alterations can cause damage!
Under no circumstances should you ever 
attempt to make alterations to the gas heating 
boiler or other parts of the system.
Never try to carry out maintenance work or 
repairs on the appliance yourself.

-  Do not damage or remove seals on components. Only 

suitably qualified heating engineer or our customer 
service may removed sealed components.

 Caution!

Risk of damage!
Do not use sprays, solvents, chlorinated 
cleaning agents, paint, adhesives or similar 
substances in the vicinity of the appliance. 
These substances can cause corrosion, 
including in the flue system.

Installation and setting

The appliance may only be installed by an suitably 
qualified heating engineer, This engineer also assumes 
responsibility for installing the appliance properly and 
putting it into service for the first time.
He is also responsible for inspection, maintenance 
and repairs to the appliance, and alterations to the set 
gas volume.

Filling pressure of the heating system

The filling pressure of the heating installation should be 
checked at regular intervals.

Emergency power supply

Your specialist technician connected your gas heating 
boiler to the electrical mains during installation.
If you wish to keep the unit running with an emergency 
power supply in the event of a power failure, the 
technical specification of the unit (frequency, voltage, 
earthing) must be in agreement with the mains power 
supply, and must be rated to at least the power 
consumption of your unit. Please consult your heating 
engineer on this subject.

Frost protection

If you are going to be away during a cold period, make 
sure the heating system remains in operation and that 
the rooms are sufficiently heated.

 Caution!

Risk of damage!
If there is a power cut or if the room 
temperature is set too low in individual rooms it 
cannot be ruled out that sections of the heating 
system are damaged by frost.
Please always observe the instructions 
concerning frost protection in Section 4.10.

Notes on the installation and operation

3.1 Vaillant 

warranty 

 

Vaillant provide a full parts and labour warranty for this 
appliance.
The appliance must be installed by a suitably competent 
person in accordance with the Gas Safety (Installation 
and Use) Regulations 1998, and the manufacturer’s 
instructions. In the UK ‘CORGI’ registered installers 
undertake the work in compliance with safe and 
satisfactory standards. 
All unvented domestic hot water cylinders must be 
installed by a competent person to the prevailing 
building regulations at the time of installation (G3).
Terms and conditions apply to the warranty, details of 
which can be found on the warranty registration card 
included with this appliance.
Failure to install and commission this appliance in 
compliance with the manufacturer’s instructions may 
invalidate the warranty (this does not affect the 
customer’s statutory rights).

3.2 Intended 

use

The Valliant atmoCRAFT gas boilers are state-of-the-art 
appliances which have been constructed in accordance 
with recognised safety regulations. Nevertheless, there 
is a risk of injury or death to the user or others and 
damage to the appliance or other property in the event 
of misuse or use for which the appliance is not intended.
The units are intended as heat generators for closed and 
open hot-water central heating installations and for 
central hot water preparation. Any other use or 
extended use is considered to be improper. The 
manufacturer or supplier is not liable for any resulting 
damage. The user alone bears the risk.
Intended use includes the observance of the operating 
and installation manual and all other applicable 
documents, as well as adherence to the maintenance 
and inspection conditions.

2 Safety
3 Notes on the installation and operation

Summary of Contents for atmoCRAFT VK SERIES

Page 1: ...VK 654 9 1654 9 atmoCRAFT DE AT GB CZ SK HU PL HR SI SCG...

Page 2: ...For the owner VK 654 9 1654 9 Operating manual atmoCRAFT Gas heating boiler GB...

Page 3: ...by exceeding the temperature 13 4 8 5 Faults with the exhaust gas removal 13 4 8 6 Filling unit heating installation 14 4 9 Shut down 14 4 10 Frost protection 15 4 10 1 Frost protection function 15 4...

Page 4: ...4 Data badge The identification plate is included with the burner and should be mounted on the separation wall 2 Safety What to do in an emergency Danger If you smell gas risk of poisoning and explos...

Page 5: ...sufficiently heated Caution Risk of damage If there is a power cut or if the room temperature is set too low in individual rooms it cannot be ruled out that sections of the heating system are damaged...

Page 6: ...en by the heating engineer The desired heating and set back phases e g at night are automatically turned on and off using the integrated time programmes Weather compensators combined with thermostat v...

Page 7: ...0 C also lead to increased lime scale production Energy conscious use of water Energy conscious use of water can reduce your bills considerably For example taking a shower instead of a bath whereas ab...

Page 8: ...nk temperature in normal mode if a storage tank sensor is connected 6 button for moving backwards in the display for adjustment and troubleshooting by the engineer 7 Reset button for resetting certain...

Page 9: ...0 6 5 4 3 bar 1 Fig 4 4 Checking the filling pressure of the heating installation pressure gauge not included Check the filling pressure of the installation using the pressure gauge 1 not included For...

Page 10: ...ng feed temperature Note We recommend a setting of 60 C for economic and hygienic reasons e g Legionella Caution Danger of calcium deposit build up If your water hardness is more than 1 79 mol m3 10 d...

Page 11: ...m fitted to your heating system 4 5 2 Setting the flow temperature no controller connected 1 2 Fig 4 8 Feed temperature setting without heating controller If there is no external controller set the fl...

Page 12: ...tion of your boiler Press the i button 1 to activate the status displays The display 2 then shows the individual status codes e g S 4 for burner operation The table below explains the most important s...

Page 13: ...he heating system see Section 4 8 2 Is there an ignition problem see Section 4 8 3 Hot water operation no problem Heating does not start Is there a requirement for heating from the external controller...

Page 14: ...exceeding the temperature 1 2 Abb 4 14 Releasing after STB switch off Your boiler is equipped with a safety temperature limiter STB which automatically switches off the boiler if the temperature gets...

Page 15: ...However in exceptions the water quality might not be suitable for filling in the heating system heavily corrosive or extremely calciferous water In a case such as this you should please contact your a...

Page 16: ...he frost protection system cannot guarantee flow through the entire heating system 4 10 2 Frost protection by draining Another way to protect the heating system and the appliance from frost is to drai...

Page 17: ...ed as follows to perform the measurements Activate the chimney sweep mode by simultaneously pushing the buttons 6 and 7 on the DIA System The measurements should be taken at the earliest after 2 minut...

Reviews: