background image

7

Operating manual atmoCRAFT

4 Operation

4.1 

Overview of the operating elements

The operating elements are accessible after folding up 
the upper section (

1

) and folding down the lower section 

(

2

) of the switching field cover.

1

2

Fig. 4.1  Opening the door in the cover

1

9

8

7

6

5

2

3

4

Fig. 4.2  Controls

The operating elements have the following functions:

1

  Display for indication of the current operating mode 

or specific additional information

2

  "

i

" button for calling up information

3

 Controller 

(accessory)

4

  Button for switching the unit on and off.

5

  "

+

" button for moving forward in the display (for 

adjustment and troubleshooting by the engineer); 
Inquiry of the current storage tank temperature in 
normal mode, if a storage tank sensor is connected.

6

  "

-

" button for moving backwards in the display (for 

adjustment and troubleshooting by the engineer)

7

  "Reset" button for resetting certain faults

8

  Rotary knob for setting the heating feed temperature

9

   Rotary knob for setting the storage tank temperature

Digital Information and Analysis System (DIA-
System)

1

Fig. 4.3  Display of DIA-System

Your unit is fitted with a Digital Information and Analysis 
System (DIA-System). This system provides information 
on the operating status of your appliance and helps you 
deal with problems.
In normal operation of the unit, the display (

1

) of the 

DIA-System shows the current heating feed temperature 
(45 °C in the example). In the event of a fault, an error 
code appears instead of the temperature.
You can also see the following information from the 
symbols displayed:

Operation 4

GB

Summary of Contents for atmoCRAFT VK SERIES

Page 1: ...VK 654 9 1654 9 atmoCRAFT DE AT GB CZ SK HU PL HR SI SCG...

Page 2: ...For the owner VK 654 9 1654 9 Operating manual atmoCRAFT Gas heating boiler GB...

Page 3: ...by exceeding the temperature 13 4 8 5 Faults with the exhaust gas removal 13 4 8 6 Filling unit heating installation 14 4 9 Shut down 14 4 10 Frost protection 15 4 10 1 Frost protection function 15 4...

Page 4: ...4 Data badge The identification plate is included with the burner and should be mounted on the separation wall 2 Safety What to do in an emergency Danger If you smell gas risk of poisoning and explos...

Page 5: ...sufficiently heated Caution Risk of damage If there is a power cut or if the room temperature is set too low in individual rooms it cannot be ruled out that sections of the heating system are damaged...

Page 6: ...en by the heating engineer The desired heating and set back phases e g at night are automatically turned on and off using the integrated time programmes Weather compensators combined with thermostat v...

Page 7: ...0 C also lead to increased lime scale production Energy conscious use of water Energy conscious use of water can reduce your bills considerably For example taking a shower instead of a bath whereas ab...

Page 8: ...nk temperature in normal mode if a storage tank sensor is connected 6 button for moving backwards in the display for adjustment and troubleshooting by the engineer 7 Reset button for resetting certain...

Page 9: ...0 6 5 4 3 bar 1 Fig 4 4 Checking the filling pressure of the heating installation pressure gauge not included Check the filling pressure of the installation using the pressure gauge 1 not included For...

Page 10: ...ng feed temperature Note We recommend a setting of 60 C for economic and hygienic reasons e g Legionella Caution Danger of calcium deposit build up If your water hardness is more than 1 79 mol m3 10 d...

Page 11: ...m fitted to your heating system 4 5 2 Setting the flow temperature no controller connected 1 2 Fig 4 8 Feed temperature setting without heating controller If there is no external controller set the fl...

Page 12: ...tion of your boiler Press the i button 1 to activate the status displays The display 2 then shows the individual status codes e g S 4 for burner operation The table below explains the most important s...

Page 13: ...he heating system see Section 4 8 2 Is there an ignition problem see Section 4 8 3 Hot water operation no problem Heating does not start Is there a requirement for heating from the external controller...

Page 14: ...exceeding the temperature 1 2 Abb 4 14 Releasing after STB switch off Your boiler is equipped with a safety temperature limiter STB which automatically switches off the boiler if the temperature gets...

Page 15: ...However in exceptions the water quality might not be suitable for filling in the heating system heavily corrosive or extremely calciferous water In a case such as this you should please contact your a...

Page 16: ...he frost protection system cannot guarantee flow through the entire heating system 4 10 2 Frost protection by draining Another way to protect the heating system and the appliance from frost is to drai...

Page 17: ...ed as follows to perform the measurements Activate the chimney sweep mode by simultaneously pushing the buttons 6 and 7 on the DIA System The measurements should be taken at the earliest after 2 minut...

Reviews: