Operation 4

0020262548_00 Operating instructions

7

4.3

Operating concept

The system control is operated using two selection buttons
and a rotary knob.

You can use the selection buttons to do the following:

Navigate through the selection levels and the setting
level in the menu structure.

Select a set value.

Confirm a set value.

Navigate to the operating modes.

Cancel changing a set value.

You can use the rotary knob to do the following:

Navigate through the list entries for a selection level.

Select a selection level or setting level.

Change a selected set value.

The display shows an element that is highlighted by white
writing on a black background. A flashing, highlighted value
means that you can change the value.

If you do not operate the system control for more than 10
seconds, the background lighting switches off.

If you do not operate the system control during a period of
more than 5 minutes, the basic display appears again.

4.3.1

Using the rotary knob to make settings in
the basic display

If the display shows the basic display, you can use the rotary
knob to change the setting for the desired temperature or
ventilation level.

The setting that you change depends on selecting the pre-
ferred display in the basic display, the selected operating
mode and the set mode for the operating mode.

4.3.1.1 Desired temperature in the Heating

operating mode

Change desired day temperature

18°C

For 6 hrs: wait 12 s

Permanent: Press OK

OK

Mode

Time
periods

Effect

Auto

On

Switch to another display view with the
request:

Permanent change to the

Day

temp. heating

Change to the

Day temp. heating

for six hours

Off

Direct change to the

Set-back temp.

heat.

for six hours

Mode

Time
periods

Effect

Day

Switch to another display view with the
request:

Permanent change to the

Day

temp. heating

Change to the

Day temp. heating

for six hours

Set-back

Direct change to the

Set-back temp.

heat.

for six hours

off

None

4.3.1.2 Desired temperature in the Cooling

operating mode

Mode

Time
periods

Effect

Auto

On

Direct permanent change to the

Day

temp. cooling

Off

None

Day

Direct permanent change to the

Day

temp. cooling

off

None

4.3.1.3 Ventilation level in the Ventilation operating

mode

Mode

Time
periods

Effect

Auto

On

Direct permanent change to the

Max.

vent. stage: Day

Off

Direct permanent change to the

Max.

vent. stge: Night

Day

Direct permanent change to the

Max.

vent. stage: Day

Set-back

Direct permanent change to the

Max.

vent. stge: Night

4.3.1.4 Desired temperature in the Manual cooling

advanced function

Mode

Time
periods

Effect

Activated

On

Direct permanent change to the

Day

temp. cooling

Off

None

4.3.1.5 Using the rotary knob to make settings with

no effect

You cannot influence the following advanced functions by
turning the rotary knob:

System OFF active

Cylinder boost

Party function

1 day at home

Days at home scheduling

1 day away from home

Days away from home scheduling

Ventilation boost

Screed-drying function

Summary of Contents for 0020236294

Page 1: ...instructions Weather compensated sys tem control VRC 700 6 GB IE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www va...

Page 2: ...er 5 3 10 CE label 5 4 Operation 5 4 1 Operating structure 5 4 2 Basic display 6 4 3 Operating concept 7 5 Operating and display functions 8 5 1 Information 9 5 2 Settings 11 5 3 Operating modes 15 5...

Page 3: ...ce conditions listed in the instruc tions This product can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabil ities or lack of experience and k...

Page 4: ...1 Heating The outdoor temperature sensor measures the outdoor temperature and forwards the values to the system control When the outdoor temperature is low the system control in creases the flow temp...

Page 5: ...age In heavily insulated rooms that only allow a small exchange of air moisture and mould damage may occur Ventilate the rooms regularly by opening windows and activate the Ventilation boost function...

Page 6: ...s the zone whose values are to appear in the ba sic display 4 2 2 Preferred operating mode in the basic display If your heating installation is designed for two of the three operating modes heating co...

Page 7: ...de Change desired day temperature 18 C For 6 hrs wait 12 s Permanent Press OK OK Mode Time periods Effect Auto On Switch to another display view with the request Permanent change to the Day temp heati...

Page 8: ...time Date time Display Back Select 6 Press the right hand selection button Select The system control switches to setting level Display The adjustable value for the Display contrast is highlighted Dis...

Page 9: ...function and press the right hand selection button OK you reset the previously totalled solar yield to 0 kWh Menu Information System status Environmental yield You can use this function to read the t...

Page 10: ...on sumption for hot water in the current month Menu Information Consumption Current month Hot water Fuel You can use this function to read the total fuel consump tion in kWh for hot water in the curre...

Page 11: ...temperature in the living rooms Set back temp heat Set a low room temperature at which the living rooms do not cool down Cooling Day temp cooling Set a comfortable room temperature in the living rooms...

Page 12: ...display and change the set times for the block marked with 5 2 3 4 Setting the Heating time programme Menu Time programmes ZONE1 The time programmes are only effective for the Heat ing operating mode...

Page 13: ...mode 5 2 6 Select language Menu Basic settings Language You can use this function to change to the language that you want to appear in the display 5 2 6 1 Setting your language 1 Press the left hand s...

Page 14: ...example 5 2 12 2 Setting the low tariff electricity rate Menu Basic settings Costs Low tariff elec rate The hybrid manager can use this function to correctly calculate the costs for the back up boiler...

Page 15: ...the system control regulates the control behaviour set by the competent person Eco The heating function is switched off and the system control monitors the outdoor temperature If the outdoor temperatu...

Page 16: ...on is active The advanced function is deactivated if the days that are set have elapsed or if the outdoor temperature falls be low 4 C If you want to set the temperature separately for more than one z...

Page 17: ...k You can read the current fault messages under Menu In formation System status Fault status As soon as a fault message occurs for the heating installation the setting level displays the value Fault l...

Page 18: ...ineer has installed the system in accordance with Vaillant instructions The system owner will be granted a warranty in accordance with the Vaillant terms and conditi ons All requests for work during t...

Page 19: ...End user level The description of the functions for ZONE1 also applies for all available zones Setting level Values Unit Increment select Default setting Min Max Information System status System Faul...

Page 20: ...month kWh Fuel Total value for the last month kWh Hot water Electricity Total value since start up kWh Fuel Total value since start up kWh Information Consumption History Heating Electricity Total va...

Page 21: ...g on the ventilation unit Time programmes ZONE1 Heating Time programmes ZONE1 Cooling Time programmes Circulation Time programmes Ventilation Individual days and blocks Monday Tuesday Wednes day Thurs...

Page 22: ...01 01 15 Time 00 00 23 59 h min 00 10 08 00 Daylight saving time Manual Auto Manual Basic settings Display Display contrast 1 15 1 9 Button lock off On off Preferred display Heating Cooling Vent Heati...

Page 23: ...ating up of the heating and the domestic hot water Heat pump does not work 1 Inform the competent person 2 Select the setting for limp home mode until the competent person arrives 3 To do this read th...

Page 24: ...he operating instruc tions of the ventilation unit for information on the maintenance work required See the operating instructions for the ventilation unit 5 Service date Next service on The competent...

Page 25: ...evel 5 Operating mode 15 Operating mode in the basic display 6 Outdoor temperature setting the offset 14 P Party 16 Preventing a malfunction 5 R Reading the article number 5 11 Reading the electrical...

Page 26: ...tions 0020262548_00 System status 9 T Time period deviating times in the block 12 Time programme 11 quick setting 12 Setting 12 V Ventilation 4 Ventilation boost 16 Ventilation level 11 Z Zone 5 11 Zo...