Troubleshooting 6

0020262548_00 Operating instructions

17

5.4.6

Activating Cylinder boost

Op. mode

Cylinder boost

The

Cylinder boost

advanced function heats the water

in the domestic hot water cylinder until it reaches the set
desired temperature

Domestic hot water

.

The advanced function is active for one hour unless you can-
cel it sooner. The heating installation then returns to the pre-
set operating mode.

5.4.7

Activating System OFF active

Op. mode

System OFF active

The

System OFF active

advanced function switches off

the heating function, the domestic hot water circuit, the
circulation and the cooling. The frost protection function
is activated.

Ventilation is activated and works at the lowest ventilation
level.

The advanced function is deactivated by cancelling the ad-
vanced function. The heating installation will then return to
the pre-set mode.

5.5

Messages

5.5.1

Maintenance message

Maintenance messages (

Appendix C)

If maintenance is required, the system control displays a
maintenance message in the display.

To prevent the heating installation from breaking down and
to prevent damage, you must pay attention to the mainten-
ance message:

Observe the operating instructions for the unit shown.

Only carry out the maintenance instructions that are de-
scribed in the operating instructions for the unit shown.

For all other maintenance instructions, inform the com-
petent person.

5.5.2

Fault message

Fault messages (

Appendix B)

A fault message with fault code (e.g. F.33) and the affected
heat generator appear in the system control's display.

Press the

Reset

selection button.

Heat generator fault clearance?

appears in the

display.

Press the

OK

selection button.

Faults are cleared for the heat generator

briefly

appears in the display.

If the fault persists, inform the competent person.

If you would like to see the basic display on the display
again, press the left-hand selection button

Back

.

You can read the current fault messages under

Menu

In-

formation

System status

Fault status

. As soon as a

fault message occurs for the heating installation, the setting
level displays the value

Fault list

. The right-hand selection

button has been assigned the

Display

function.

6

Troubleshooting

Troubleshooting faults (

Appendix B)

6.1

Implementing the setting if the heat pump
fails

If the fault message

Restricted operation/ comfort pro-

tection Inactive

appears on the display, the heat pump has

failed and the system control enters limp home mode. The
back-up boiler now supplies the heating installation with
heating energy. During installation, the competent person
has restricted the temperature for limp home mode. You can
feel that the domestic hot water and heating are not becom-
ing very hot.

While you wait for the competent person to come, you can
use the rotary knob to implement the following settings:

Inactive

: The system control works in limp home mode;

heating and domestic hot water become moderately hot.

Heating

: The back-up boiler takes over the heating mode;

the heating becomes hot, the domestic hot water is cold.

DHW

: The back-up boiler takes over the domestic hot water

mode; the domestic hot water becomes hot, the heating is
cold.

DHW+heat.

: The back-up boiler takes over the heating and

domestic hot water mode; the heating and the domestic hot
water become hot.

The back-up boiler is not as efficient as the heat pump,
meaning that using only the back-up boiler to generate heat
is expensive.

If you want to implement settings on the system control, click

Back

and the basic display appears in the display. After five

minutes of no operation, the fault message appears again in
the display.

7

Care

7.1

Caring for the product

Clean the casing with a damp cloth and a little solvent-
free soap.

Do not use sprays, scouring agents, detergents, solvents
or cleaning agents that contain chlorine.

8

Decommissioning

8.1

Decommissioning the product

If you want to replace or remove the product, you must de-
commission the heating installation.

This work should be carried out by a competent person.

Summary of Contents for 0020236294

Page 1: ...instructions Weather compensated sys tem control VRC 700 6 GB IE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www va...

Page 2: ...er 5 3 10 CE label 5 4 Operation 5 4 1 Operating structure 5 4 2 Basic display 6 4 3 Operating concept 7 5 Operating and display functions 8 5 1 Information 9 5 2 Settings 11 5 3 Operating modes 15 5...

Page 3: ...ce conditions listed in the instruc tions This product can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabil ities or lack of experience and k...

Page 4: ...1 Heating The outdoor temperature sensor measures the outdoor temperature and forwards the values to the system control When the outdoor temperature is low the system control in creases the flow temp...

Page 5: ...age In heavily insulated rooms that only allow a small exchange of air moisture and mould damage may occur Ventilate the rooms regularly by opening windows and activate the Ventilation boost function...

Page 6: ...s the zone whose values are to appear in the ba sic display 4 2 2 Preferred operating mode in the basic display If your heating installation is designed for two of the three operating modes heating co...

Page 7: ...de Change desired day temperature 18 C For 6 hrs wait 12 s Permanent Press OK OK Mode Time periods Effect Auto On Switch to another display view with the request Permanent change to the Day temp heati...

Page 8: ...time Date time Display Back Select 6 Press the right hand selection button Select The system control switches to setting level Display The adjustable value for the Display contrast is highlighted Dis...

Page 9: ...function and press the right hand selection button OK you reset the previously totalled solar yield to 0 kWh Menu Information System status Environmental yield You can use this function to read the t...

Page 10: ...on sumption for hot water in the current month Menu Information Consumption Current month Hot water Fuel You can use this function to read the total fuel consump tion in kWh for hot water in the curre...

Page 11: ...temperature in the living rooms Set back temp heat Set a low room temperature at which the living rooms do not cool down Cooling Day temp cooling Set a comfortable room temperature in the living rooms...

Page 12: ...display and change the set times for the block marked with 5 2 3 4 Setting the Heating time programme Menu Time programmes ZONE1 The time programmes are only effective for the Heat ing operating mode...

Page 13: ...mode 5 2 6 Select language Menu Basic settings Language You can use this function to change to the language that you want to appear in the display 5 2 6 1 Setting your language 1 Press the left hand s...

Page 14: ...example 5 2 12 2 Setting the low tariff electricity rate Menu Basic settings Costs Low tariff elec rate The hybrid manager can use this function to correctly calculate the costs for the back up boiler...

Page 15: ...the system control regulates the control behaviour set by the competent person Eco The heating function is switched off and the system control monitors the outdoor temperature If the outdoor temperatu...

Page 16: ...on is active The advanced function is deactivated if the days that are set have elapsed or if the outdoor temperature falls be low 4 C If you want to set the temperature separately for more than one z...

Page 17: ...k You can read the current fault messages under Menu In formation System status Fault status As soon as a fault message occurs for the heating installation the setting level displays the value Fault l...

Page 18: ...ineer has installed the system in accordance with Vaillant instructions The system owner will be granted a warranty in accordance with the Vaillant terms and conditi ons All requests for work during t...

Page 19: ...End user level The description of the functions for ZONE1 also applies for all available zones Setting level Values Unit Increment select Default setting Min Max Information System status System Faul...

Page 20: ...month kWh Fuel Total value for the last month kWh Hot water Electricity Total value since start up kWh Fuel Total value since start up kWh Information Consumption History Heating Electricity Total va...

Page 21: ...g on the ventilation unit Time programmes ZONE1 Heating Time programmes ZONE1 Cooling Time programmes Circulation Time programmes Ventilation Individual days and blocks Monday Tuesday Wednes day Thurs...

Page 22: ...01 01 15 Time 00 00 23 59 h min 00 10 08 00 Daylight saving time Manual Auto Manual Basic settings Display Display contrast 1 15 1 9 Button lock off On off Preferred display Heating Cooling Vent Heati...

Page 23: ...ating up of the heating and the domestic hot water Heat pump does not work 1 Inform the competent person 2 Select the setting for limp home mode until the competent person arrives 3 To do this read th...

Page 24: ...he operating instruc tions of the ventilation unit for information on the maintenance work required See the operating instructions for the ventilation unit 5 Service date Next service on The competent...

Page 25: ...evel 5 Operating mode 15 Operating mode in the basic display 6 Outdoor temperature setting the offset 14 P Party 16 Preventing a malfunction 5 R Reading the article number 5 11 Reading the electrical...

Page 26: ...tions 0020262548_00 System status 9 T Time period deviating times in the block 12 Time programme 11 quick setting 12 Setting 12 V Ventilation 4 Ventilation boost 16 Ventilation level 11 Z Zone 5 11 Zo...

Page 27: ......

Page 28: ...e DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer...

Reviews: