2 Notes on the documentation

4

Operating instructions 0020262548_00

2

Notes on the documentation

2.1

Observing other applicable documents

You must observe all operating instructions enclosed with
the system components.

2.2

Storing documents

Keep this manual and all other applicable documents
safe for future use.

2.3

Validity of the instructions

These instructions apply only to:

VRC 700/6

article number

Great Britain

0020184838

2.4

Nomenclature

The following terms are used for simplification:

System control: This refers to the

VRC 700

system con-

trol.

Remote control: If this refers to the

VR 91

remote control.

2.5

Function availability

The functions described in these operating instructions are
not available for all system configurations.

The system control only shows the functions that are avail-
able in the system configuration you have installed.

3

Product description

3.1

Design of the product

1

2

3

4

5

6

5

1

Display

2

Wall-mounting base

3

Diagnostics socket

4

Wall-mounting base
cover

5

Selection button

6

Rotary knob

3.2

Main function

The system control is a weather-compensated system con-
trol with an outdoor temperature sensor installed in the open
air.

The system control is connected to the outdoor temperature
sensor and the heat generator. The system control controls
the heating installation and other connected components,
e.g. the domestic hot water generation for a connected do-
mestic hot water cylinder or the ventilation of a connected
ventilation unit.

3.2.1

Heating

The outdoor temperature sensor measures the outdoor
temperature and forwards the values to the system control.
When the outdoor temperature is low, the system control in-
creases the flow temperature of the heating installation. If the
outdoor temperature increases, the system control reduces
the flow temperature. The system control responds to the
fluctuations in the outdoor temperature and uses the flow
temperature to ensure that the room temperature remains at
the desired temperature.

3.2.2

Cooling

The room temperature sensor measures the room temper-
ature and sends the data to the system control. If the room
temperature is higher than the desired temperature that is
set, the system control switches cooling on.

3.2.3

Ventilation

Using a controlled exchange of air, the ventilation unit en-
sures that the living rooms are ventilated and aerated. The
system control controls the air volume flow via the ventilation
levels that are set.

3.2.4

Domestic hot water generation

A temperature sensor measures the temperature of the wa-
ter in the domestic hot water cylinder and forwards the val-
ues to the system control. If the temperature lies below the
set value, the system control increases the temperature in
the domestic hot water circuit and therefore heats up the wa-
ter to the set domestic hot water temperature.

3.2.5

Circulation

The secondary return pipe is connected to the domestic hot
water pipe and forms a circuit with the domestic hot water
cylinder. The circulation pump pumps the domestic hot water
through the domestic hot water pipe, either continuously or
on a time-controlled basis. This means that domestic hot
water is available at the draw-off points.

Summary of Contents for 0020236294

Page 1: ...instructions Weather compensated sys tem control VRC 700 6 GB IE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www va...

Page 2: ...er 5 3 10 CE label 5 4 Operation 5 4 1 Operating structure 5 4 2 Basic display 6 4 3 Operating concept 7 5 Operating and display functions 8 5 1 Information 9 5 2 Settings 11 5 3 Operating modes 15 5...

Page 3: ...ce conditions listed in the instruc tions This product can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabil ities or lack of experience and k...

Page 4: ...1 Heating The outdoor temperature sensor measures the outdoor temperature and forwards the values to the system control When the outdoor temperature is low the system control in creases the flow temp...

Page 5: ...age In heavily insulated rooms that only allow a small exchange of air moisture and mould damage may occur Ventilate the rooms regularly by opening windows and activate the Ventilation boost function...

Page 6: ...s the zone whose values are to appear in the ba sic display 4 2 2 Preferred operating mode in the basic display If your heating installation is designed for two of the three operating modes heating co...

Page 7: ...de Change desired day temperature 18 C For 6 hrs wait 12 s Permanent Press OK OK Mode Time periods Effect Auto On Switch to another display view with the request Permanent change to the Day temp heati...

Page 8: ...time Date time Display Back Select 6 Press the right hand selection button Select The system control switches to setting level Display The adjustable value for the Display contrast is highlighted Dis...

Page 9: ...function and press the right hand selection button OK you reset the previously totalled solar yield to 0 kWh Menu Information System status Environmental yield You can use this function to read the t...

Page 10: ...on sumption for hot water in the current month Menu Information Consumption Current month Hot water Fuel You can use this function to read the total fuel consump tion in kWh for hot water in the curre...

Page 11: ...temperature in the living rooms Set back temp heat Set a low room temperature at which the living rooms do not cool down Cooling Day temp cooling Set a comfortable room temperature in the living rooms...

Page 12: ...display and change the set times for the block marked with 5 2 3 4 Setting the Heating time programme Menu Time programmes ZONE1 The time programmes are only effective for the Heat ing operating mode...

Page 13: ...mode 5 2 6 Select language Menu Basic settings Language You can use this function to change to the language that you want to appear in the display 5 2 6 1 Setting your language 1 Press the left hand s...

Page 14: ...example 5 2 12 2 Setting the low tariff electricity rate Menu Basic settings Costs Low tariff elec rate The hybrid manager can use this function to correctly calculate the costs for the back up boiler...

Page 15: ...the system control regulates the control behaviour set by the competent person Eco The heating function is switched off and the system control monitors the outdoor temperature If the outdoor temperatu...

Page 16: ...on is active The advanced function is deactivated if the days that are set have elapsed or if the outdoor temperature falls be low 4 C If you want to set the temperature separately for more than one z...

Page 17: ...k You can read the current fault messages under Menu In formation System status Fault status As soon as a fault message occurs for the heating installation the setting level displays the value Fault l...

Page 18: ...ineer has installed the system in accordance with Vaillant instructions The system owner will be granted a warranty in accordance with the Vaillant terms and conditi ons All requests for work during t...

Page 19: ...End user level The description of the functions for ZONE1 also applies for all available zones Setting level Values Unit Increment select Default setting Min Max Information System status System Faul...

Page 20: ...month kWh Fuel Total value for the last month kWh Hot water Electricity Total value since start up kWh Fuel Total value since start up kWh Information Consumption History Heating Electricity Total va...

Page 21: ...g on the ventilation unit Time programmes ZONE1 Heating Time programmes ZONE1 Cooling Time programmes Circulation Time programmes Ventilation Individual days and blocks Monday Tuesday Wednes day Thurs...

Page 22: ...01 01 15 Time 00 00 23 59 h min 00 10 08 00 Daylight saving time Manual Auto Manual Basic settings Display Display contrast 1 15 1 9 Button lock off On off Preferred display Heating Cooling Vent Heati...

Page 23: ...ating up of the heating and the domestic hot water Heat pump does not work 1 Inform the competent person 2 Select the setting for limp home mode until the competent person arrives 3 To do this read th...

Page 24: ...he operating instruc tions of the ventilation unit for information on the maintenance work required See the operating instructions for the ventilation unit 5 Service date Next service on The competent...

Page 25: ...evel 5 Operating mode 15 Operating mode in the basic display 6 Outdoor temperature setting the offset 14 P Party 16 Preventing a malfunction 5 R Reading the article number 5 11 Reading the electrical...

Page 26: ...tions 0020262548_00 System status 9 T Time period deviating times in the block 12 Time programme 11 quick setting 12 Setting 12 V Ventilation 4 Ventilation boost 16 Ventilation level 11 Z Zone 5 11 Zo...

Page 27: ......

Page 28: ...e DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer...

Reviews: