Appendix
0020271929_00 atmoMAG Installation and maintenance instructions
27
MAG 114/1 G(E-
BE/FR)
MAG 114/1 G(H-
DACH)
MAG 114/1 G(LL-
DE)
MAG 114/1 G(P-
BE/FR)
Net weight
10.9 kg
10.9 kg
10.9 kg
10.9 kg
Gross weight
13.8 kg
13.8 kg
13.8 kg
13.8 kg
Test symbol/registration no.
1008CS3137
1008CS3137
1008CS3137
1008CS3137
MAG 114/1 G(P-CH)
MAG 144/1 G(E-BE)
MAG 144/1 G(H-AT)
MAG 144/1 G(H-
DE/CH)
Designated country (designation in
accordance with ISO 3166)
CH
BE
AT
CH, DE
Approved gas boiler category
II
2H3P
I
2E+
, I
3P
II
2H3P
II
2ELL 3P
(DE), II
2H3P
(CH)
Unit dimensions, height
680 mm
680 mm
680 mm
680 mm
Unit dimensions, width
350 mm
350 mm
350 mm
350 mm
Unit dimensions, depth (incl. rotary
switch)
270 mm
270 mm
270 mm
270 mm
Flue pipe connection diameter
110 mm
130 mm
130 mm
130 mm
Min. length of the flue pipe
0.5 m
0.5 m
0.5 m
0.5 m
Gas connection diameter
1/2
″
conical
1/2
″
conical
1/2
″
conical
1/2
″
conical
Water connection diameter (inlet)
G1/2
″
G1/2
″
G1/2
″
G1/2
″
Water connection diameter (outlet)
G1/2
″
G1/2
″
G1/2
″
G1/2
″
Net weight
10.9 kg
12.2 kg
12.2 kg
12.2 kg
Gross weight
13.8 kg
15.1 kg
15.1 kg
15.1 kg
Test symbol/registration no.
1008CS3137
1008CS3137
1008CS3137
1008CS3137
MAG 144/1 G(LL-
DE)
MAG 144/1 G(P-BE)
MAG 144/1 G(P-CH)
Designated country (designation in
accordance with ISO 3166)
EN
BE
CH
Approved gas boiler category
II
2ELL 3P
I
2E+
, I
3P
II
2H3P
Unit dimensions, height
680 mm
680 mm
680 mm
Unit dimensions, width
350 mm
350 mm
350 mm
Unit dimensions, depth (incl. rotary
switch)
270 mm
270 mm
270 mm
Flue pipe connection diameter
130 mm
130 mm
130 mm
Min. length of the flue pipe
0.5 m
0.5 m
0.5 m
Gas connection diameter
1/2
″
conical
1/2
″
conical
1/2
″
conical
Water connection diameter (inlet)
G1/2
″
G1/2
″
G1/2
″
Water connection diameter (outlet)
G1/2
″
G1/2
″
G1/2
″
Net weight
12.2 kg
12.2 kg
12.2 kg
Gross weight
15.1 kg
15.1 kg
15.1 kg
Test symbol/registration no.
1008CS3137
1008CS3137
1008CS3137
Technical data
–
Power/load
Applicability:
Germany
OR Austria
OR Switzerland
OR Belgium
MAG 114/1 G(LL-
DE)
MAG 114/1 G(E-
BE/FR)
MAG 114/1 G(H-
DACH)
MAG 114/1 G(LL-
DE)
Domestic hot water volume at the
"hot" temperature selector position
2.6 … 5.5 l/min
2.6 … 5.5 l/min
2.6 … 5.5 l/min
2.6 … 5.5 l/min
Domestic hot water volume at the
"warm" temperature selector position
5.4 … 11.0 l/min
5.4 … 11.0 l/min
5.4 … 11.0 l/min
5.4 … 11.0 l/min
Max. heat input (in relation to the net
calorific value H
i
)
21.7 kW
21.7 kW
21.7 kW
21.7 kW