10
Use in the field
10.1
Variable sown amount
By pressing the field for the seed application rate in the
work display, a pop-up window for variable application
rate appears.
The variable application rate is controlled directly on the
home screen by selecting the percentage change.
The percentage change is recorded in the calibration
menu, see
.
Figure 10.1 Pop-up window for variable sown amount
Adjust the control to the desired change. 0% means no
change.
10.2
Setting tramlines
The work display shows the tramlining cycle.
The first number shows which phase of the tramlining
cycle you are in.
The second digit shows the number of tramlining cycles
in the tramlining program, see
for
setting the tramlining cycle.
Green symbol = tramlining enabled.
White symbol = tramlining is disabled.
Red symbol = indicates a problem with tramlining.
Step in the tramlining program by tapping the field
Figure 10.2
A. Steps back in the tramlining program
B. Steps forward in the tramlining program
C. Restarts the tramlining program on 1
D. Confirms any change in the sequence
To step in the program, tap + or - until the desired
drawbar is displayed in the program and then press Done.
To close the dialog box without making any changes, tap
outside the box.
A
B
C
D
26