Troubleshooting
96
Ver.3 29/06/07
18 Seed fan, low rpm.
- Check that the hydraulic hoses have been correctly
connected to the tractor.
- Check whether the hydraulic oil flow from the tractor
has been correctly set.
- Check the alarm time limits that were programmed
into the Control Station.
- Check the cable, connectors and connections of the
rpm sensor.
- Check the function of the sensor by turning the fan
wheel by hand and also verifying that the sensor LED
lights. The LED should light when the pin on the fan
shaft passes. The distance between the sensor and the
pin should be 1 - 2 mm. Adjust if necessary. A lit
LED, however, is not necessarily any guarantee that
the sensor is operating.
See ”
4.18 Replacing the fan revolution sensor” on
for replacement of the sensor.
- If the alarm is generated intermittently, a likely cause
is incorrect adjustment of the sensor or a defective
sensor.
19 Seed fan, high rpm.
- Check whether the hydraulic oil flow from the tractor
has been correctly set.
- Check the alarm time limits that were programmed
into the Control Station.
22 Seed output valve - max.
power.
- This valve, which controls the flow to the hydraulic
motor driving the seed output, opens fully.
- Check the oil flow from the tractor, the hoses and the
couplings.
- Check whether seed output is blocked or whether
there is another problem.
23 High voltage Workstation 1.
- The tractor supplies a voltage of more than 17 V. The
Control Station remains on, but certain functions,
such as electric motors and hydraulic valves, are
switched off.
24 High voltage Workstation 2.
- The tractor supplies a voltage of more than 17 V. The
Control Station remains on, but certain functions,
such as electric motors and hydraulic valves, are
switched off.
25 Seed box clutch, right-hand
side.
- This alarm is generated when seed shut-off on the
right side does not operate.
- Check the cable, switch and connection of the mag-
netic clutch in the right seed box. An LED on the seed
box switch lights when the clutch receives current.
The clutch should then stop the feed roller. If the
alarm is generated although the LED lights, a likely
cause is a defective magnetic clutch.
Summary of Contents for RAPID RDA S Series
Page 1: ...Ver 3 29 06 07 900236 dk Instruktioner S maskine RAPID serie RDA 600 800 S Nr 12 800 14 799...
Page 2: ...2 Ver 3 29 06 07...
Page 17: ...RDA 600 800 S Ver 3 29 06 07 17...
Page 20: ...Instructions and settings 20 Ver 3 29 06 07 2 8 Horizontal alignment Figure 2 18 A E C D B...
Page 71: ...RDA 600 800 S Ver 3 29 06 07 71 Figure 4 4...
Page 104: ...Appendices 104 Ver 3 29 06 07 6 3 2 Hydraulic diagram RDA 800 S Figure 6 2 444639...
Page 116: ...Appendices 116 Ver 3 29 06 07...
Page 117: ......