RDA 600-800 S
Ver.3 29/06/07
91
The drill cannot be raised and/or
lowered!
- Check whether the lift stop or low-lift mode has been
set.
- See ”
5.1.2 Hydraulic fault” on page 86.
If the drill cannot be raised:
- Check whether the lift stop or low-lift mode has been
set.
- See ”
5.1.2 Hydraulic fault” on page 86.
- Check whether the lift stop valve (C) receives current
as a result of a shortcircuit or another fault. See
Hy-
draulic electric valves
under ”
- Switch off the Control Station and check whether the
drill can be raised. If it is still not possible to raise the
machine, the fault can be found in the hydraulic sys-
tem.
- Check whether a shortcircuit has occurred in the cable
harness or the intermediate cable and which function
is affected.
The Control Station generates an
alarm of too low or too high fan
speed!
-
NOTE!
The alarm is not generated if the fan hose has
come loose or the ejector elbows are not in the correct
positions.
Hydraulic fan:
- Check whether the hydraulic hoses are correctly con-
nected and that the hydraulic connector is pressurized.
- Check the programming of the Control Station.
- Have the pressure and flow been correctly set on the
tractor (130 bars and at least 35 l/min.)? Has the flow
valve of the tractor been correctly set?
- Has the fan speed regulator been correctly set? (Op-
tional; this is used when the tractor does not feature an
inherent flow regulator device.)
Summary of Contents for RAPID RDA S Series
Page 1: ...Ver 3 29 06 07 900236 dk Instruktioner S maskine RAPID serie RDA 600 800 S Nr 12 800 14 799...
Page 2: ...2 Ver 3 29 06 07...
Page 17: ...RDA 600 800 S Ver 3 29 06 07 17...
Page 20: ...Instructions and settings 20 Ver 3 29 06 07 2 8 Horizontal alignment Figure 2 18 A E C D B...
Page 71: ...RDA 600 800 S Ver 3 29 06 07 71 Figure 4 4...
Page 104: ...Appendices 104 Ver 3 29 06 07 6 3 2 Hydraulic diagram RDA 800 S Figure 6 2 444639...
Page 116: ...Appendices 116 Ver 3 29 06 07...
Page 117: ......