Camera settings
Use the DIP switch array to set other camera behaviors.
Note
When the camera is right side up, switches are in their default positions when they are up.
Camera identification:
If a Vaddio remote control will be used with the camera:
IR Frequency
Selection:
The IR Remote Commander can control up to three cameras in the same room with different IR
frequencies. Use
switches 1 and 2
to select the frequency to identify the camera as camera 1, 2, or 3;
then use the Camera Select buttons at the top of the remote to select the camera you want to control.
IR:
Leave
switch 3
in the default up position if the IR remote will be used.
Inverted operation:
If mounting the camera upside-down, set
switch 4
(IMAGE FLIP) ON.
Super Wide Mode (RoboSHOT 12 only):
To set Super-wide mode for the RoboSHOT 12 HDMI, set
switch 5
ON. This gives a 12X, 73º horizontal angle of view. Normal mode produces a 67.2º horizontal
field of view (HFOV). Super-wide mode is not available on RoboSHOT 30 cameras.
RS-232 Serial Baud Rate:
Set the baud rate for RS-232 communication using
switch 6
. Most
applications use 9600bps (switch 6 OFF). The 9600 bps setting works best with Cat-5e over distance. Use
the 38,400 bps setting for short control lines only.
Switch 7
is not currently used.
Switch 8
is not currently used.
8