OneLINK Device Configuration
After installation is complete and the OneLINK device and camera are operational, you will need to change
the AEC reference if you made the audio connections as shown in these diagrams.
On the Audio page of the OneLINK Bridge web interface, set Master Output/AEC Reference to Output 2 if
using Line Out 2 for the speaker connection.
Camera Configuration
Point the remote at the camera and press the Data Screen button to see the camera's IP address on the
connected display.
You can configure the following settings on your Vaddio HDBaseT camera:
n
HDMI output resolution: Depending on the camera, set this using the rotary switch on the back of the
camera or the virtual rotary switch on DIP Switches tab of the System page.
n
IP streaming: Streaming page. Settings include Enable/disable, streaming quality, and streaming
resolution.
n
Codec Control Mode: Soft DIP on the DIP Switches tab of the System page.
n
IR: ON (default). DIP switch 3 on the back of RoboSHOT 20 UHD or RoboSHOT HDBT cameras, soft
DIP 3 on the DIP Switches tab of the System page for DocCAM 20 HDBT.
Note
Codec Control Mode was added to Vaddio cameras in early 2018. Your camera may require a firmware
update to add this capability.
21