RoboSHOT HDBT Camera and Polycom RealPresence Group 700 Codec
Other Vaddio HDBaseT cameras connect in the same way.
Hardware Note: IR Forwarding
Although the OneLINK Bridge does not support IR forwarding, the two unterminated wires of the fan-out
cable can be terminated and connected to an IR emitter (repeater).
Hardware Note: Connection and Configuration Changes
After connecting or configuring the equipment, reboot the OneLINK device, camera, and codec. Note that
rebooting the OneLINK device does not affect the camera and codec; they must be rebooted separately.
Camera Configuration
Point the remote at the camera and press the Data Screen button to see the camera's IP address on the
connected display.
You can configure the following settings on your Vaddio HDBaseT camera:
n
HDMI output resolution: Depending on the camera, set this using the rotary switch on the back of the
camera or the virtual rotary switch on DIP Switches tab of the System page.
n
IP streaming: Streaming page. Settings include Enable/disable, streaming quality, and streaming
resolution.
n
Codec Control Mode: Soft DIP on the DIP Switches tab of the System page.
n
IR: ON (default). DIP switch 3 on the back of RoboSHOT 20 UHD or RoboSHOT HDBT cameras, soft
DIP 3 on the DIP Switches tab of the System page for DocCAM 20 HDBT.
Note
Codec Control Mode was added to Vaddio cameras in early 2018. Your camera may require a firmware
update to add this capability.
16