background image

page 16 of 17

Documents are only to be used and distributed completely and unchanged. It is strictly the users´ responsibility to check
carefully the validity of this document with respect to his product. manual-no.: 999039 / 16/12/2009

Konformitätserklärung

Declaration of conformity

Déclaration de conformité

Vakuum-Controller / Vacuum controller / Régulateur de vide

DVR 5 (230V; 682910, 682911, 682912)

VAP 5 (230V; 682850, 682858, 682881, 682880)

Hiermit erklären wir, dass das oben bezeichnete Gerät in Konzeption und Bauart sowie in der von uns in
Verkehr gebrachten Ausführung den grundlegenden Anforderungen der zutreffenden, aufgeführten EU-
Richtlinien entspricht. Bei einer mit uns nicht abgestimmten Änderung an dem Gerät verliert diese Erklä-
rung ihre Gültigkeit.
We herewith declare that the product designated above is in compliance with the basic requirements of
the applicable EC-directives stated below with regard to design, type and model sold by us. This certificate
ceases to be valid if the product is modified without the agreement of the manufacturer.

Par la présente, nous déclarons que le dispositif désigné ci-dessus est conforme aux prescriptions de
base des directives EU applicables et indiqués en ci que concerne conception, dessin et modèle vendu par
nous-mêmes. Cette déclaration cesse d´être valable si des modifications sont apportées au dispositif
sans notre autorisation préalable.

Niederspannungsrichtlinie / Low-Voltage Directive / Directive Basse Tension
2006/95/EG
Richtlinie Elektromagnetische Verträglichkeit / Electromagnetic Compatibility Directive / Directive
Compatibilité Electromagnétique
2004/108/EG
Angewandte Harmonisierte Normen / Harmonized Standards applied / Normes Harmonisées utilisées
DIN EN 61010-1, DIN EN 61326-1
Managementsysteme / Management systems / Systèmes de Management
EN ISO 9001, EN ISO 14001 (1997-2006)

VACUUBRAND GMBH + CO KG

-Vakuumtechnik im System-

-Technology for Vacuum Systems-

-Technologie pour système à vide-

. . . . . . . . . . . . . . . . . . . . . . . . . . . .
(Dr. F. Gitmans)
Geschäftsführer / Managing Director / Gérant

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ort, Datum / place, date / lieu, date

Wertheim,  16.12.2009

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(Dr. J. Dirscherl)
Technischer Leiter / Technical Director / Directeur technique

ppa.

Alfred-Zippe-Str. 4 - 97877 Wertheim
Tel.: +49  9342 808-0 - Fax: +49 9342 808-450
E-Mail: [email protected]
Web: www.vacuubrand.com

Summary of Contents for VAP 5

Page 1: ...buted completely and unchanged It is strictly the users responsibility to check carefully the validity of this document with respect to his product manual no 999039 16 12 2009 Vacuum gauges VAP 5 DVR...

Page 2: ...controller VACUUBRAND vacuum gauges are the result of many years of experience in construction and practical operation of these vacuum gauges combined with the latest results in material and manufact...

Page 3: ...his product manual no 999039 16 12 2009 Attention Important notes Not permitted Misuse may cause damage Caution Hot surface Isolate equipment from mains Note Contents Safety information 4 Technical d...

Page 4: ...ination withVACUUBRAND genuine accessories Obey all other relevant safety requirements e g accident prevention regulations for working in laboratories and explosion protection guidelines and provide p...

Page 5: ...sary is approximately decontaminated before starting maintenance Use only genuine spare parts and accessories Otherwise safety and performance of the equipment as well as the electromagnetic compatibi...

Page 6: ...0 1 n i h t i w e u l a v d e t a c i d n i f o 0 1 r a b m 0 0 1 2 r a b m e g n a r t i g i d 1 r a b m 1 t n e i c i f f e o c e r u t a r e p m e T d e i f i c e p s t o n K r a b m 7 0 0 n o i t...

Page 7: ...peration Display Rear side key button for digital adjustment and electronic scale conversion pressure unit at the side of the housing male connector for mains cable thread M8 for stand rod female conn...

Page 8: ...yed with a resolution of 0 1 mbar in the range of 0 1 to 10 mbar and with a resolution of 1 mbar for pressures 10 mbar Preparing for operation Connect gauge head with connecting cable to the female co...

Page 9: ...ace the actual pressure value can be read out The single abbreviations of a command are separated by underscores ASCII 5FH The string is terminated with CR LF ASCII 0DH ASCII 0AH r e t e m a r a p e c...

Page 10: ...d a e h e g u a G d e t a n i m a t n o c r o r e t l i f e v i t c e t o r p n a e l C y r a s s e c e n f i e n o w e n e s u d n a d a e h e g u a g n a e l C t s u j d a e r g n o r w s i t n e m...

Page 11: ...h the pumped media see Technical data If the vacuum system is contaminated oil particles etc Replace the protective filter cat no 63 87 29 in the gauge head VSP 5 if necessary Using small screw driver...

Page 12: ...not be adjusted under vacuum replace gauge head Push key button at the side of the housing with a pencil tip or a small screwdriver Status indication readjustment Set is displayed Disconnect leads fro...

Page 13: ...ey button to adjust the display to the reference pressure at the vacuum line within the range of 0 10 mbar Note If the nominal ultimate vacuum of a diaphragm pump is used as reference vacuum the accur...

Page 14: ...ry product returned for repair We submit quotations only on request and always at the customer s expense If an order is given the costs incurred are offset from the costs for repair or from the pur ch...

Page 15: ...for the returned product that neither toxic corrosive biologically active explosive radio active nor contamination dangerous in any way has occurred the product is free of dangerous substances the oil...

Page 16: ...agreement of the manufacturer Par la pr sente nous d clarons que le dispositif d sign ci dessus est conforme aux prescriptions de base des directives EU applicables et indiqu s en ci que concerne con...

Page 17: ...obtained under test conditions for specific applications depend on a number of factors beyond our control It is therefore strictly the users responsibility to very carefully check the validity of app...

Reviews: