TECHNICAL DATA
vacon • 13
24-hour support: +358 (0)40 837 1150 • Email: [email protected]
4
4.
TECHNICAL DATA
4.1
Power ratings
4.1.1
Vacon NXP/C 5 – Mains voltage 380—500 V
High overload = Max current I
S
, 2 sec/20 sec, Rated overload current, 1 min/10 min
Following continuous operation at rated output current, rated overload current
for 1 min, followed by a period of load current less than rated current, and of
such duration that the r.m.s output current, over the duty cycle, does not exceed
rated output current (IH)
Low overload = Max current I
S
, 2 sec/20 sec, Rated overload current, 1 min/10 min
Following continuous operation at rated output current, rated overload current
for 1 min, followed by a period of load current less than rated current, and of
such duration that the r.m.s output current, over the duty cycle, does not exceed
rated output current (IL)
Mains voltage 380-500 V, 50/60 Hz, 3~
Loadability
Motor shaft power
Low High
400V supply
500V supply
Frequency
converter
type
Rated
contin.
current I
L
(A)
Rated
overload
current
(A)
Rated
contin.
current I
H
(A)
Rated
overload
current
(A)
Max
current
I
S
Low
overload
P(kW)
High
overload
P(kW)
Low
overload
P(kW)
High
overload
P(kW)
Frame
Dimensions and
weight*
WxHxD/kg
NX_0261 5
261
287
205
308
349
132
110
160
132
FR9
606x2275x605/371
NX_0300 5
300
330
245
368
444
160
132
200
160
FR9
606x2275x605/371
NX_0385 5
385
424
300
450
540
200
160
250
200
FR10
606x2275x605/371
NX_0460 5
460
506
385
578
693
250
200
315
250
FR10
606x2275x605/403
NX_0520 5
520
572
460
690
828
250
250
355
315
FR10
606x2275x605/403
NX_0590 5
590
649
520
780
936
315
250
400
355
FR11
806x2275x605/577
NX_0650 5
650
715
590
885
1062
355
315
450
400
FR11
806x2275x605/577
NX_0730 5
730
803
650
975
1170
400
355
500
450
FR11
806x2275x605/577
NX_0820 5
820
902
730
1095
1314
450
400
560
500
FR12
1206x2275x605/810
NX_0920 5
920
1012
820
1230
1476
500
450
630
560
FR12
1206x2275x605/810
NX_1030 5
1030
1133
920
1380
1656
560
500
710
630
FR12
1206x2275x605/810
NX_1150 5
1150
1265
1030
1545
1620
630
560
800
710
FR13 1406X2275X605/1000
NX_1300 5
1300
1430
1150
1725
2079
710
630
900
800
FR13 1806X2275X605/1100
NX_1450 5
1450
1595
1300
1950
2484
800
710
1000
900
FR13 1806X2275X605/1100
NX_1770 5
1770
1947
1600
2400
2880
1000
900
1200
1100
FR14 2806X2275X605/2440
NX_2150 5
2150
2365
1940
2910
3492
1200
1100
1500
1300
FR14 2806X2275X605/2500
Table 4-1. Power ratings and dimensions of Vacon NX, supply voltage 380—500V.
Note: The rated currents in given ambient temperatures are achieved only when the switching fre-
quency is equal to or less than the factory default (automatic thermal management).
*The dimensions indicated are for the basic 6-pulse IP21 version of the converter cabinet. Some op-
tions may increase the width, height or weight of the cabinet. See the delivery-specific documenta-
tion for more details.