32
• vacon
Profinet IO
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
2
Bits
Description
Value = 0
Value = 1
0
OFF
ON
1
Coast stop (No OFF2 / OFF2)
No coast stop
2
Quick stop (No OFF3 / OFF3)
No quick stop
3
Disable operation
Enable operation
4
Reset ramp generator
b
Enable ramp generator
b
5
Freeze ramp generator
b
Unfreeze ramp generator
b
6
Disable setpoint
Enable setpoint
7
Fault acknowledgement (0->1)
8
Jog 1 OFF
a
Jog 1 ON
a
9
Jog 2 OFF
a
Jog 2 ON
a
10
No control by PLC
Control by PLC
11
Device-specific
12-15
Device-specific
a
Optional; depends on application
b
Depends on application
5.3.1.2.
ZSW1
ZSW1 is the Profidrive profile’s status word. Status word indicates information about the status of
the device. Also messages are indicated in the Status word. The ZSW1 Status word is composed of
16 bits that have the following meanings:
Bits
Description
Value = 0
Value = 1
0
Not ready to switch on
Ready to swich on
1
Not ready to operate
Ready to operate
2
Operation disabled
Operation enabled (drive follows set-
point)
3
No fault
Fault present
4
Coast stop activated (No OFF2 / OFF2)
Coast stop not activated
5
Quick stop activated (No OFF3 / OFF3)
Quick stop not activated
6
Switching on not inhibited
Switching on inhibited
7
No warning
Warning present
8
Speed error out of tolerance range
Speed error within tolerance range
9
No control requested
Control requested
10
f or n not reached
f or n reached or exceeded
11
Device-specific
12
Device-specific
13
Device-specific
14-15
Device-specific