ENGLISH
- 45 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
Pot
Motor power
60
(STD)
100
(FAST)
30 - 100
The displayed value is the percentage of max. motor power
P.rAL
Power motor during slow-down phase
20
0 - 70
The value displayed represents the percentage of the maximum
motor power
SPUn
Start off
If this function is activated, for the first 2 seconds of motion of each
door, the control unit will ignore
Pot
value and it will give motor the
maximum power command in order to overcome the gate inertia
no
no
Function deactivated
Si
Function activated
rAM
Starting ramp
2
(STD)
3
(FAST)
4 - 0
(STD)
6 - 0
(FAST)
In order not to stress too much the motor, when the motion starts
the power is gradually increased, until reached the set value or 100%
if the take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is
the time necessary to reach the value of nominal power.
SEnS
Adjusting the obstacle sensor
no
no
Function deactivated
1.0A-15.0A
(STD)
1.0A-18.0A
(FAST)
This menu allows adjustment of the sensitivity of the obstacle sensor.
When the current absorbed by the motor exceeds the value set, the
control unit detects an alarm
rA.AP
Slow down in opening
15
(STD)
25
(FAST)
0 - 100
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last opening stretch
rA.Ch
Slow down in closing
15
(STD)
25
(FAST)
0 - 100
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last closing stretch
St.AP
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the opening phase
PAUS
PAUS
The gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate go on with the opening phase (command is ignored)
St.Ch
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the closing phase
StoP
StoP
The gate stops and its cycle is considered as finished
APEr
The gate opens again
St.PA
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a
Start command when the gate is open during its pause phase
ChiU
ChiU
The gate starts closing
no
Command is ignored
PAUS
The pause time is reset (
Ch.AU
)
Summary of Contents for TORQ-D
Page 2: ...300 3 325 88 5 88 5 161 177 70 325 5 150 185...
Page 28: ...ITALIANO 26...
Page 54: ...ENGLISH 52...
Page 80: ...FRAN AIS 78...
Page 106: ...ESPA OL 104...
Page 132: ...130 PORTUGU S...
Page 158: ...DEUTSCH 156...
Page 184: ...NEDERLANDS 182...
Page 185: ......
Page 186: ......
Page 187: ......