ENGLISH
- 12 -
DESCRIPTION OF THE CONTROL UNIT
• Programming achieved using program buttons and display
• 230V power supply for 1 single-phase motor
• LED courtesy light integrated into the container
• Control keypad located on the cover
• Plug-in adaptor for modular radio receiver MR2
• Up, stop, down inputs
• Up, stop, down and courtesy light controls from transmitter
• 1 photocell input with self-test function
• 1 mechanical, resistive or optical-type safety edge input with
self-test function
• 1 emergency (fire alarm / alarm) input
• 24V accessory power supply output
• 230V flashing light/courtesy light output
• Optical-type safety edge power adjustment output
• Plug-in terminal boards
• Monitoring of input status shown by display
TECHNICAL SPECIFICATIONS
Power supply
230 V / 50 Hz
Max motor load
1100 W
Max accessories load 30 Vdc 3 W
Working temperature
-20 ÷ +60 °C
Protection fuse
F1 = 5A ritardato
Dimensions
170 x 185 x 70 mm
Weight
800 g
Protection
IP55
ELECTRIC CONNECTIONS
L1
START/UP. N.O. contact
L2
STOP. N.C. contact
L3
COMMON (-)
L4
DOWN. N.O. contact
L5
PHOTOCELL. N.C. contact
L6
EDGE. N.C. contact
(Safety edge - parameter
in5
=
oFF
)
FCA. N.C. contact
(Opening limit switch - parameter
in5
=
on
)
L7
FIRE. N.C. contact
(Alarm - parameter
in5
=
oFF
)
FCC. N.C. contact
(Closing limit switch - parameter
in5
=
on
)
L8
COM (-). Common
L9
Adjustment of the power for OPTICAL SAFETY EDGE
L10
+30 Vdc power output for photocells and other
accessories
L11
+30 Vdc power supply for functional test TX photocell
E1 - E2
Flashing light 230Vac
(parameter
ou1
=
oFF
)
Courtesy light 230Vac
(parameter
ou1
=
on
)
E3
Motor open
E4
Motor common
E5
Motor close
N
230Vac power supply - neutral
L
230Vac power supply - phase
A1
Antenna shield
A2
Antenna