background image

ENGLISH

- 12 -

DESCRIPTION OF THE CONTROL UNIT

•  Programming achieved using program buttons and display
•  230V power supply for 1 single-phase motor
•  LED courtesy light integrated into the container
•  Control keypad located on the cover
•  Plug-in adaptor for modular radio receiver MR2
•  Up, stop, down inputs
•  Up, stop, down and courtesy light controls from transmitter
•  1 photocell input with self-test function
•  1 mechanical, resistive or optical-type safety edge input with 

self-test function

•  1 emergency (fire alarm / alarm) input
•  24V accessory power supply output
•  230V flashing light/courtesy light output
•  Optical-type safety edge power adjustment output
•  Plug-in terminal boards
•  Monitoring of input status shown by display

TECHNICAL SPECIFICATIONS

Power supply

230 V  /  50 Hz

Max motor load

1100 W

Max accessories load 30 Vdc 3 W

Working temperature

-20 ÷ +60 °C

Protection fuse

F1 = 5A ritardato

Dimensions

170 x 185 x 70 mm

Weight

800 g

Protection

IP55

ELECTRIC CONNECTIONS

L1

START/UP. N.O. contact

L2

STOP. N.C. contact

L3

COMMON (-)

L4

DOWN. N.O. contact

L5

PHOTOCELL. N.C. contact

L6

EDGE. N.C. contact
(Safety edge - parameter 

in5 

oFF

)

FCA. N.C. contact
(Opening limit switch - parameter 

in5

 = 

on

)

L7

FIRE. N.C. contact
(Alarm - parameter 

in5

 = 

oFF

)

FCC. N.C. contact
(Closing limit switch - parameter 

in5

 = 

on

)

L8

COM (-). Common 

L9

Adjustment of the power for OPTICAL SAFETY EDGE

L10

+30 Vdc power output for photocells and other 
accessories

L11

+30 Vdc power supply for functional test TX photocell

E1 - E2

Flashing light 230Vac
(parameter 

ou1

 = 

oFF

)

Courtesy light 230Vac 
(parameter 

ou1 

on

)

E3

Motor open

E4

Motor common

E5

Motor close

N

230Vac power supply - neutral

L

230Vac power supply - phase

A1

Antenna shield

A2

Antenna 

Summary of Contents for KIT EASY LUX

Page 1: ...LI GB DIGITAL CONTROL UNIT FOR ROLLER SHUTTERS F ARMOIRE DE COMMANDE DIGITALE POUR STORES E CUADRO DE MANIOBRAS DIGITAL PARA PERSIANAS ENROLLABLES P QUADRO EL CTRICO DIGITAL PARA ESTORES DE ENROLAR D...

Page 2: ...ed out by qualified personnel only who can issue the Compliance Certificate concerning the whole installation EEC Machine Directive 89 392 Annex IIA The automated vehicular gates shall comply with the...

Page 3: ...ONS Power supply 230 V 50 Hz Max motor load 1100 W Max accessories load 30 Vdc 3 W Working temperature 20 60 C Protection fuse F1 5A ritardato Dimensions 170 x 185 x 70 mm Weight 800 g Protection IP55...

Page 4: ...GE ADJUSTMENT 30VDC 3W 30VDC 3W for Photo TX test OPEN COM CLOSE NEUTRAL PHASE ANT RECEIVER L1 L2 A2 A1 L3 L4 L5 E1 E2 E3 E4 E5 N F1 L L6 L7 L8 L9 L10 L11 mWARNING Normally closed inputs STOP L2 PHOTO...

Page 5: ...o 5 function is set to EMERGENCY OPTICAL EDGE INSTALLATION The EASY LUX main control unit is configured for the installation of one 24 Vdc powered optical edge and transmitter power regulation Connect...

Page 6: ...mode can be used to move the gate in DEAD MAN mode in particular cases such as installation maintenance or in the case of malfunctioning of photocell edge limit switches or encoder To activate the fu...

Page 7: ...e AUX channel on the panel used by WES EASY is not working FS the door is already at its limit in the required direction 0P the operator has stopped the operation by pressing a button on the control u...

Page 8: ...igured to manage a mechanical safety edge RESISTIVE RUBBER OPTICAL SAFETY EDGE The L6 input is configured to manage a safety edge resistive rubber optical with active operation test If the test fails...