INPUTS

DISPLAY

oFF

on

dEF1 dEF2 dEF3 dEF4

in 1

PHOTOCELL ACTIVE ONLY DURING 
CLOSING

The intervention of the photocell during 
the opening stage is ignored. 
The intervention of the photocell during 
the closing stage causes the shutter to 
reopen.

PHOTOCELL ACTIVE DURING OPENING AND 
CLOSING

The intervention of the photocell during the 
opening phase causes the motor to stop.
When the photocell beam is released, the 
automation starts during opening for the work 
time set in parameter 

t i1

.

The intervention of the photocell during the 
closing stage causes the shutter to reopen.

on

oFF

oFF

on

in 2

PHOTOCELL TEST INACTIVE

The photocell operation test is not
performed

PHOTOCELL TEST ACTIVE

Each time the control unit receives an open or 
close command, the PHOTOCELL TEST verifies 
that the PHOTOCELL is operating correctly.

If the test fails, the display shows 

- L5 -

oFF

oFF

oFF

oFF

in 3

MECHANICAL SAFETY EDGE

The L6 input is configured to manage a 
mechanical safety edge

RESISTIVE RUBBER / OPTICAL SAFETY EDGE

The L6 input is configured to manage a safety 
edge (resistive rubber / optical) with active 
operation test.

If the test fails, the display shows 

- L6 -

oFF

on

oFF

oFF

in 4

FIRE FUNCTION

The L7 input is configured to manage a 
fire alarm

ALARM FUNCTION

The L7 input is configured to manage an  
anti-theft command

oFF

oFF

oFF

oFF

in 5

EDGE / FIRE FUNCTION

The L6 input is configured to manage a 
safety edge
The L7 input is configured to manage 
an alarm 

LIMIT SWITCH FUNCTION

The L6 input is configured to manage an opening 
limit switch
The L6 input is configured to manage a closing 
limit switch

NOTE: 

If 

in 5 

is set on the settings of the 

in 3 

and 

in 4 

functions, they are not considered

oFF

oFF

oFF

oFF

in 6

DISABLING OF THE SAFETY EDGE 
WHILE CLOSING

Function off

DISABLING OF THE SAFETY EDGE WHILE 
CLOSING

In case of irregular floors, you might have to 
disable the safety edge on the last closing section 
of the door (max. 5cm) to prevent any unwanted 
enabling of the edge.

To set the point at which to disable the edge, 
follow the procedure on page 20.

oFF

oFF

oFF

oFF

Summary of Contents for KIT EASY LUX

Page 1: ...LI GB DIGITAL CONTROL UNIT FOR ROLLER SHUTTERS F ARMOIRE DE COMMANDE DIGITALE POUR STORES E CUADRO DE MANIOBRAS DIGITAL PARA PERSIANAS ENROLLABLES P QUADRO EL CTRICO DIGITAL PARA ESTORES DE ENROLAR D...

Page 2: ...ed out by qualified personnel only who can issue the Compliance Certificate concerning the whole installation EEC Machine Directive 89 392 Annex IIA The automated vehicular gates shall comply with the...

Page 3: ...ONS Power supply 230 V 50 Hz Max motor load 1100 W Max accessories load 30 Vdc 3 W Working temperature 20 60 C Protection fuse F1 5A ritardato Dimensions 170 x 185 x 70 mm Weight 800 g Protection IP55...

Page 4: ...GE ADJUSTMENT 30VDC 3W 30VDC 3W for Photo TX test OPEN COM CLOSE NEUTRAL PHASE ANT RECEIVER L1 L2 A2 A1 L3 L4 L5 E1 E2 E3 E4 E5 N F1 L L6 L7 L8 L9 L10 L11 mWARNING Normally closed inputs STOP L2 PHOTO...

Page 5: ...o 5 function is set to EMERGENCY OPTICAL EDGE INSTALLATION The EASY LUX main control unit is configured for the installation of one 24 Vdc powered optical edge and transmitter power regulation Connect...

Page 6: ...mode can be used to move the gate in DEAD MAN mode in particular cases such as installation maintenance or in the case of malfunctioning of photocell edge limit switches or encoder To activate the fu...

Page 7: ...e AUX channel on the panel used by WES EASY is not working FS the door is already at its limit in the required direction 0P the operator has stopped the operation by pressing a button on the control u...

Page 8: ...igured to manage a mechanical safety edge RESISTIVE RUBBER OPTICAL SAFETY EDGE The L6 input is configured to manage a safety edge resistive rubber optical with active operation test If the test fails...

Page 9: ...The user must press and hold the start button for the entire duration of the desired opening or closing procedure The maximum duration of opening or closing depends on the operating time set DEAD MAN...

Page 10: ...DEAD MAN LOGIC FROM BUTTON AND FROM THE TRANSMITTER The dead man logic can be activated via buttons terminal board and push button panel and from the transmitter oFF oFF on oFF Lo 8 DEAD MAN LOGIC ACT...

Page 11: ...Perform several opening and closing cycles to check that the obstacles are properly detected and make sure the door closes even if the edge presses against the floor Cancelling the function If you wa...

Reviews: