ENGLISH
- 19 -
OPERATING LOGIC
DISPLAY
oFF
on
dEF1 dEF2 dEF3 dEF4
Lo 5
TIMER FUNCTION
Each time the timer closes the contact
L1-L3, the automation starts during
opening and remains paused until the
contact is released.
EMERGENCY DEAD-MAN FUNCTION
If a command is rejected due to an active safety
switch, you can activate the man mode on the
emergency switch (page 15) to move the shutter.
When the command is suspended, the control
unit returns to the mode set.
This way, it is possible to move the shutter when
there is evidence of a fault on a safety.
oFF
on
oFF
oFF
Lo 6
THE INTERVENTION OF THE
SAFETY EDGE DOES NOT DISABLE
AUTOMATIC CLOSING
THE INTERVENTION OF THE SAFETY
DISABLES AUTOMATIC CLOSING
on
oFF
oFF
on
Lo 7
DEAD MAN LOGIC FROM BUTTON
The dead-man logic can only be
activated via buttons (terminal board
and push button panel).
DEAD MAN LOGIC FROM BUTTON AND
FROM THE TRANSMITTER
The dead-man logic can be activated via buttons
(terminal board and push button panel) and from
the transmitter.
oFF
oFF
on
oFF
Lo 8
DEAD MAN LOGIC ACTIVATED
DURING OPENING AND CLOSING
DEAD MAN LOGIC ACTIVATED ONLY DURING
CLOSING
oFF
oFF
on
oFF
Lo 9
PRE-FLASHING DISABLED
PRE-FLASHING ENABLED
The pre-flashing time depends on the settings
made for parameter
Lo 10
oFF
on
oFF
oFF
Lo 10
PRE-FLASHING TIME
Before activating the motor during
opening, the indicator flashes for 1
second.
Before activating the motor during
closing, the indicator flashes for 3
seconds.
PRE-FLASHING TIME
Before activating the motor during opening &
closing, the indicator flashes for 3 seconds.
oFF
on
oFF
oFF
WORKING TIMES
DISPLAY FUNCTION
AVAILABLE VALUES
dEF1 dEF2 dEF3 dEF4
ti 1
WORK TIME
7” - 1 0” - 1 5” - 20” - 30” - 45” - 60”
75” - 90” - 1 20”
20”
30”
30”
20”
ti 2
PAUSE TIME
1 0” - 1 5” - 20” - 30” - 45” - 60”
90” - 1 20” - 1 80” - 250”
30”
1 5”
1 5”
30”
ti 3
DELAYED TURNING OFF OF THE
COURTESY LIGHTS
3” - 5” - 1 0” - 20” - 30” - 1’00
2’00 - 5’00 - 10’0 - 20’0
3”
3”
2’00 2’00