EASY-LUX

Summary of Contents for KIT EASY LUX

Page 1: ...LI GB DIGITAL CONTROL UNIT FOR ROLLER SHUTTERS F ARMOIRE DE COMMANDE DIGITALE POUR STORES E CUADRO DE MANIOBRAS DIGITAL PARA PERSIANAS ENROLLABLES P QUADRO EL CTRICO DIGITAL PARA ESTORES DE ENROLAR D...

Page 2: ...ed out by qualified personnel only who can issue the Compliance Certificate concerning the whole installation EEC Machine Directive 89 392 Annex IIA The automated vehicular gates shall comply with the...

Page 3: ...ONS Power supply 230 V 50 Hz Max motor load 1100 W Max accessories load 30 Vdc 3 W Working temperature 20 60 C Protection fuse F1 5A ritardato Dimensions 170 x 185 x 70 mm Weight 800 g Protection IP55...

Page 4: ...GE ADJUSTMENT 30VDC 3W 30VDC 3W for Photo TX test OPEN COM CLOSE NEUTRAL PHASE ANT RECEIVER L1 L2 A2 A1 L3 L4 L5 E1 E2 E3 E4 E5 N F1 L L6 L7 L8 L9 L10 L11 mWARNING Normally closed inputs STOP L2 PHOTO...

Page 5: ...o 5 function is set to EMERGENCY OPTICAL EDGE INSTALLATION The EASY LUX main control unit is configured for the installation of one 24 Vdc powered optical edge and transmitter power regulation Connect...

Page 6: ...mode can be used to move the gate in DEAD MAN mode in particular cases such as installation maintenance or in the case of malfunctioning of photocell edge limit switches or encoder To activate the fu...

Page 7: ...e AUX channel on the panel used by WES EASY is not working FS the door is already at its limit in the required direction 0P the operator has stopped the operation by pressing a button on the control u...

Page 8: ...igured to manage a mechanical safety edge RESISTIVE RUBBER OPTICAL SAFETY EDGE The L6 input is configured to manage a safety edge resistive rubber optical with active operation test If the test fails...

Page 9: ...The user must press and hold the start button for the entire duration of the desired opening or closing procedure The maximum duration of opening or closing depends on the operating time set DEAD MAN...

Page 10: ...DEAD MAN LOGIC FROM BUTTON AND FROM THE TRANSMITTER The dead man logic can be activated via buttons terminal board and push button panel and from the transmitter oFF oFF on oFF Lo 8 DEAD MAN LOGIC ACT...

Page 11: ...Perform several opening and closing cycles to check that the obstacles are properly detected and make sure the door closes even if the edge presses against the floor Cancelling the function If you wa...