DESCRIPTION OF THE CONTROL UNIT

The CITY11 control unit is an innovative V2 product guaranteeing 
safety and reliability for swing gate automation.
The CITY11 design has been aimed at creating a product which 
adapts to suit all needs, thus obtaining an extremely versatile 
control unit satisfying all the necessary requirements for a
functional and efficient installation.

•  230V - 50Hz or 120V - 60Hz power supplies, depending on the 

model, for 2 single phase motors (700W global).

•  Output for 12V electric lock.

•  Input for keyswitch or push-button.

•  Input for safety photocell.

•  Input for safety edge, capable of handling standard edges 

with switch normally closed and conductive rubber edges with 
nominal resistance of 8.2 kOhms.

•  Pre-opening safety device testing.

•  Dip-switch programmable operational logic.

•  Adjustment of motor power and operation time by means of a 

trimmer.

•  Quick plug-in connector for inserting a MR series receiver.

•  LED monitoring of inputs.

•  Courtesy light output.

•  IP55 casing

INSTALLATION

Installation of the control unit, the safety devices and accessories 
must be performed with the power supply disconnected.

POWER SUPPLY

The control unit must be powered by means of a 230 V - 50 Hz 
or 120 V - 60 Hz power line, depending on the model, protected 
by a differential magnetothermal switch in compliance with legal 
regulations. 

Connect the power cables to the control unit 

L

 and 

N

 terminals.

MOTORS

The control unit can control one or two asynchronous AC motors. 
If the control unit is used to control only one motor, then this 
must be connected to the terminals relating to motor 1.

Connect the cables for motor 1 as follows:
•  Opening cable to terminal 

K3

•  Closing cable to terminal 

K5

•  Common return cable to terminal 

K4

•  Start-up capacitor between terminals 

K3 

and 

K5

Connect the cables for motor 2 (if present) as follows:
•  Opening cable to terminal 

K6

•  Closing cable to terminal 

K8

•  Common return cable to terminal 

K7

•  Start-up capacitor between terminals 

K6 

and 

K8

PHOTOCELLS

The control unit has a 24VAC power supply for photocells with 
switch normally closed, and can perform an operational test 
before to starting the gate opening procedure. 

The photocell can be used with two settings:

1.  Photocell always active:  

Intervention of the photocell during opening or closing causes 
the gate to stop. When the photocell restores, the gate re-
opens completely.

2.  Photocell NOT active during opening:  

Intervention of the photocell during opening is ignored. 
Intervention of the photocell during closing causes the gate to 
re-open completely.

Independently of the setting selected, when the gate is paused 
while opening, the time count for any automatic re-closure will 
only start after the photocell restores.

•  Connect the photocell transmitter power cables between 

terminals 

L8 

(GND) and 

L9 

(+) on the control unit.

•  Connect the photocell receiver power cables between terminals 

L8 

(GND) and 

L7 

(+) on the control unit.

•  Connect the photocell receiver output between terminals 

L4 

and 

L6

 on the control unit.

SAFETY EDGES

The control unit has an input for controlling safety edges; this 
input is capable of controlling standard edges with switch 
normally closed and conductive rubber edges with nominal 
resistance of 8.2 kOhms.

Edges can be used with two settings:

1.  Edge always active:  

Intervention of the edge during opening or closing causes 
inversion of the direction of movement in order to free the 
body that caused the edge to intervene. The gate stops after 
approx. 3 seconds.

2.  Edge NOT active during opening: 

Intervention of the edge during opening is ignored. 
Intervention of the edge during closing causes the gate to  
re-open completely.

Independently of the settings selected, any subsequent automatic 
re-closure will be cancelled.

Standard edge with switch normally closed: 

connect the edge 

cables between terminals 

L5 

and 

L6 

on the control unit.

In order to satisfy the requirements of standard EN12978, it 
is necessary to install safety edges with a control unit which 
constantly monitors correct operation. If control units are used 
with the option of running tests by means of interrupting the 
power supply, connect the control unit power supply cables 
between terminals L8 (GND) and L9 (+). 

Conductive rubber edge:

 connect the edge cables between 

terminals 

L5

 and 

L6

 on the control unit.

m

 

PLEASE NOTE: operational testing on edges is 

reserved for standard edges (only if equipped with suitable 
control units). 

DO NOT enable testing if conductive rubber edges are used 
or standard edges used without a suitable control unit for 
controlling function.

Summary of Contents for CITY11

Page 1: ...not come into contact with safety low voltage ones The plastic case has an IP55 insulation to connect flexible or rigid pipes use pipefittings having the same insulation level Installation requires m...

Page 2: ...an be used with two settings 1 Photocell always active Intervention of the photocell during opening or closing causes the gate to stop When the photocell restores the gate re opens completely 2 Photoc...

Page 3: ...closed In both modes it is possible to disable the Start command during gate opening by means of dip switch 3 Connect the start input control device cables between terminals L1 and L6 on the control...

Page 4: ...an opening command for a standard connection device with switch normally open L3 STOP command N C switch L4 Photocell N C switch L5 Edge Switch N C or resistive rubber edge L6 Commands common line L7...

Page 5: ...h the slow down function disabled DIP 5 OFF mWARNING the adjustment of times has to be made when the gate is still POWER MIN MAX WORK 50 18 2 2 45 PAUSE 150 30 2 2 90 DELAY 90 15 0 0 45 POWER motor po...

Page 6: ...upplemental time in order to compensate for the inertia of the gate 8 Photocell ON Always active Intervention of the photocell during opening or closing causes the gate to stop When the photocell rest...

Page 7: ...cas de d tachement d un conducteur on vite que les partie en tension puissent aller en contact avec les parties faible tension de s curit Pour la connexion de tubes rigides ou flexibles utiliser des...

Reviews: