11 Care and maintenance
▸ Close the air inlet flap
4
again.
▸ Put back the front filter
3
and engage. Ensure it is
positioned correctly.
▸ Put back the front insert
1
.
3
An incorrectly inserted front filter can cause damage to the appliance!
The appliance will not start without the front filter being correctly in place.
11.4
Cleaning the front insert
▸ Close the air inlet flap
1
.
▸ Reach into the openings of the front insert
2
,
gently lift the front insert
2
and remove.
▸ Clean the front insert
2
under running water.
▸ Put back the front insert
2
.
1
2
11.5
Cleaning the moisture sensor
If the «A3» error message appears, the moisture sensor must be cleaned.
▸ Open appliance door.
1
▸ Remove any fluff or foreign objects on the mois-
ture sensor
1
.
▸ If necessary, clean moisture sensor
1
with a
damp cloth and wipe dry.
1
11.6
Cleaning the temperature sensor
Carefully clean the temperature sensor!
▸ Press the air inlet flap down until the magnetic
holder releases.
1
33