ATTENTION
The electrical power supply should be provided by a magneto thermic switch adequate to the power
of the machine.
Also, there should always be installed a high sensitivity differential switch with a cut-off threshold of
Idn=0.030 A.
It is necessary that the machine is earthed in such a way as to guarantee a contact voltage of no
more than 25V.
Operation of the machine should be carried out in such a way that damage cannot be caused to
people or property and, wherever possible, away from paths of transit.
12
Attach the lance to the high pressure hose (1) and the other end to the output connection (2).
Fit the sheath (B) in order to protect the hydraulic connection and to avoid the risk of scalding
by contact. The high pressure pump is supplied already full of lubricating oil. Attach a water tube
(not supplied) to the entry connection (3) and the other end to the tap of the water source (4)
which must be able to provide a minimum flow rate equal to that of the pump.
Check that the electric supply socket has the appropriate characteristics and differential protection,
and conforms to safety standards in force, then insert the plug into the power socket.
Wherever possible, avoid the use of extension cables with the electrical supply cable.