RAPID-VSC-DEM
Instructions - user maintenance manual
-
©02/20 Rev:1.0
/TRANSLATION OF THE ORIGINAL
INSTRUCTIONS
Page 44
CHAPTER 16 - T
EMPORARY DECOMMISSIONING OF THE PRESSURE WASHER
If you decide to keep the machine idle for a long period of time, it is advisable to carry out some operations to keep the
machine in good condition.
It is necessary to:
•
End a work cycle.
•
Switch off the machine and remove the connections to the water supply and the connection to the power socket (if any)
•
Empty the hydraulic circuits and the diesel tank.
•
Store the machine in a place protected from the elements
•
cover with a cloth to protect against dust.
Carry out these operations with care so that the equipment is in optimum condition when the work is resumed
CHAPTER 17 - S
OUND
E
MISSION
The Leq equivalent level averaged over multiple processing cycles (including footwear change stages) was measured with
Class 1 precision sound level meter as set out in IEC standards with fast-slow reading constant, both from the position
where the operator is, and in positions surrounding the machine being considered. There is a phonometric report at the
company.
In view of the results of continuous use of the machine, the use of anti-noise devices such as ear plugs or ear muffs is
mandatory.
The measured value is Lp(A)= 91 dB and the sound power level is Lw= 108 dB