RAPID-VSC-DEM
Instructions - user maintenance manual
-
©02/20 Rev:1.0
/TRANSLATION OF THE ORIGINAL
INSTRUCTIONS
Page 34
•
Reset the thermostat
(tr
),
•
Keep the gun open (
3
) and allow the water to cool;
•
Act on the burner off switch (
br
),
•
Close the water supply tap (
2
),
•
Act on the switch (
in
) to deactivate the engine/pump unit
•
Actuate the gun lever (
3
) in order to release the residual pressure.
A
TTENTION
The use operations described in this chapter must be carried out
ONLY
by qualified and authorised
personnel.
Use personal protective equipment during operation.
In the event of a lack of fuel oil, the solenoid valve closes, the flue gases are expelled from the flues, the
boiler switches off and the pilot light (d) comes on:
•
switch off the machine,
•
fill the fuel tank (1),
•
reset by pressing the switch (in).
In the event of a water shortage: the machine switches off and the warning light (f) comes on:
•
check the connection to the water mains (2) (low pressure circuit),
•
reset by pressing the switch (in).
If there are micro leaks, the machine switches off and the indicator light (e) flashes:
•
check the machine's high-pressure water circuit
•
reset by pressing the switch (in).
The machine is equipped with the TST system (Total Stop Timed): it switches off when the water gun
is closed, after 15 seconds and the indicator light (e) comes on.
The machine is equipped with a TSI system (Total Intelligent Stop), so it shuts down after 40 minutes
from closing the gun. The indicator light (e) flashes.
Reset by pressing the switch (in).