27
5.5.4.7 Anti Reverse
Interface
Description
Anti Reverse : Whether Inverter isn’t allowed to generate
electricity to the Grid.
The default option is disabled. It's means inverter allowed to
generate electricity to the Grid.
Anti Reverse
1.DISABLE
2.ENABLE
5.5.5 BAT SETTING
5.5.5.1 BAT SETTING
Interface
Description
This interface is used to select battery parameters.
Press Up/Down button to move corresponding options;
Press Enter button to enter the selected menu;
Press ESC button to return to setting interface.
BAT SETTING
1.BAT TYPE
2.DISC-DEPTH
3.CHARG-CURR
4.BAT-COMM
5.5.5.1.1 BAT TYPE
Interface
Description
This interface is used to select battery type.
Press Up/Down button to move corresponding options;
Press Enter button to enter the selected menu.
Select the LEAD-ACID enter button to enter LEAD-ACID
interface;
Set 1 to test and disable the setting.
BAT TYPE
1.DC-SOURCE
2.LEAD-ACID
3.Lithum
5.5.5.1.1.1 Lead-acid battery parameter
Interface
Description
LEAD-ACID
1.CHARG-VOLT
2.BAT END VOLT
3:BAT OVP
4:BAT CAP
CHARGE VOLT
INPUT: 135.0
UNIT:
V
This interface is used to select LEAD-ACID battery
parameter.
Press Up/Down button to move corresponding options;
Press Enter button to enter the selected menu;
1. Charge voltage
2. BAT end voltage
3. BAT over voltage
This interface is used to set the lead acid battery charging
voltage. (T
h
e inpt value ranges from 135 to 600)
Summary of Contents for VT-66036103