![V-TAC VT-66036103 Instruction Manual Download Page 17](http://html1.mh-extra.com/html/v-tac/vt-66036103/vt-66036103_instruction-manual_3108239017.webp)
14
Step5. Plug the PV
connector
into the corresponding PV connector on inverter.
4.3
Battery Connection
Ø
Note
1.Before choosing battery, please note the maximum voltage of battery can not exceed 59V and the
rated voltage of battery can not exceed 48V, and the battery communication should be compatible
with Hybrid inverter.
2.
Before connecting to
battery
, please install a nonpolarized DC
(125A)
breaker to make sure inverter
can be securely disconnected during
maintenance
.
3.The connecting cable between the battery and the inverter shall be at least 4AWG
.
4
.The battery communication can only work when the battery BMS is compatible with the inverter.
5.To replace the battery, you need to turn off all switches and unplug the system communication line.
6.All the above wiring and operations must be carried out after the whole machine is powered down,
and all of them need professional personnel to complete
Ø
Power Connection Steps:
Step1. Choose the
4
AWG wire and strip the cable to 15mm.
Step2. Select two O-terminals with an aperture of M6.
Step3. Insert the stripping line into the O-terminal and clamp it with a crimping clamp.
Step1,2,3.
Step4. Remove waterproof cover plate.
Step5. Disassemble the waterproof connector and pass the cable through the
waterproof connector.
Step4.
Step5.
Summary of Contents for VT-66036103