6)
1)
Check that the coupling jaw is properly
locked in the central position.
Limits shown on page 19/32,
those parts shall be replaced
with new ones immediately.
If during the various checks, any
component wear has exceeded the
N
O
T
E
Depending on the use and at least annually the coupling shall be
checked for wear.
The following checks and controls are recommended:
This chapter refers also to the figure on page 21/32.
Checking the rubber buffers
Take hold of the coupling and check it, by shaking it forcefully. There
should be no play.
If vertical play exceeds 1 mm the inner bush (7c) must be
replaced. If there is any longitudinal play, the rubber buffers
(8a,8b) must be replaced - see chapter 5.1 REPLACEMENT OF
RUBBER BUFFERS AND INNER BUSH, page 21/32.
4.1 PERIODICAL MAINTENANCE
REV. 00
CHAP. 4
PAG.
18/32
DRAWBAR COUPLING E 40
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
Summary of Contents for E 40