3�2�3 Wall mounting with integrated ball joint and cable-hose-package
Preparations on the machine tool:
At the chosen position a Ø30mm hole is needed in the machine wall. This should preferably be done
with a step drill or a sheet metal punch.
Installation of wall mount, wall connection and camera:
Guide the wall mount (no. 1) with the attached flat seal (no. 4) from the interior of the machine through
the hole. On the outside of the machine, the wall mount must now be tightened with a washer (no. 7)
and the nut (no. 2).
On the outside of the machine, a hose connector (Pos.5) is screwed into the wall mount.
First guide the cables, which hang out of the connecting sleeve (no. 9) of the camera, through the wall
mount (no. 1) into the control box. Then push the connecting sleeve (no. 9) with the O-ring (no. 8) into
the wall mount (no. 1). In this step, you can already roughly align the camera. The fine adjustment can
be done later via the integrated ball joint. Fix the camera by tightening the union nut (no.6).
1. wall mount
2. nut M30x1,5
3. machine wall
4. flat seal
5. hose connector
6. union nut
7. washer
8. o-ring
9. connection sleeve
If you additionally use an optional wall bushing „double socket“ for this installation variant, please
follow the instructions in chapter 3.2.4.
Ideally, you should use the cable duct at the side of the control box for this mounting variant.
You have two optionpossibilities to mountfix the control box:
1. You can use the optionally available magnetic feet for our control box.
2. You attach the control box to your machine with suitable screws.