SCUBAPRO S600-S550 SECOND STAGES
2003 SCUBAPRO
Important note
: The following information is not designed to be a complete training guide for servicing the listed SCUBAPRO regulators. All SCUBAPRO
technicians are required to attend an annual service training program to insure safe handling and servicing of SCUBAPRO products. All SCUBAPRO technicians
must be employed by an authorized SCUBAPRO facility.
7
P/N
43
04
00
00
TOOLS
NEEDED
No tools needed
this step
Turn the breathing effort adjustment
knob clockwise until it is no longer in
contact with the balance adjustment
mechanism.
Remove the breathing effort
adjustment knob.
Using 3mm jeweler’s screwdriver turn
the balance adjustment mechanism
clockwise and remove.
Turn the 3mm jeweler’s screwdriver
clockwise to disassemble the
remainder of the balance adjustment
mechanism.
Remove all o’rings.
Remove the knob plug using the
universal tool.