SCUBAPRO S600-S550 SECOND STAGES
2003 SCUBAPRO
Important note
: The following information is not designed to be a complete training guide for servicing the listed SCUBAPRO regulators. All SCUBAPRO
technicians are required to attend an annual service training program to insure safe handling and servicing of SCUBAPRO products. All SCUBAPRO technicians
must be employed by an authorized SCUBAPRO facility.
18
Adjusting the balance
chamber counter
clockwise reduces
cracking effort.
Adjusting the balance
chamber clockwise
increases cracking effort.
Inspect and lubricate the external
adjustment knob o’ring.
Re-install external breathing
adjustment knob and tighten using the
Philips screwdriver.
Make any additional adjustments using
the pneumatic adjusting tool.
Re-install the “anti-set chamber” and
tighten until it is flush with the outside
of the cracking effort adjustment knob.
Make any additional adjustments using
the pneumatic adjusting tool and
balance chamber adjusting tool.