7
5. Connect 1 in. NPT pipe or garden hose to pump
(A) discharge.
For garden hose connections,
thread adapter (B) into the discharge before
connecting the hose.
B
BOOSTING WATER PRESSURE
6. Connect 1 in. NPT pipe or garden hose to pump
(A) as in step 2. Connect the other end of the
inlet line to water supply such as a spigot.
Connect outlet pipe or hose to pump (A).
Do not run pump (A) with outlet
pipe or nozzle closed. The hose may burst
from excessive pressure. Use only reinforced
high-pressure hose or pipe for outlet pipe when
boosting water pressure.
A
A
A
Outlet
Inlet
6
Outlet with
1 in. NPT
PVC
Outlet with
adapter and
garden hose
5
DISCHARGE
PRESSURE (PSI)
GALLONS PER
HOUR
5
800
10
700
17
600
25
500
30
400
40
200
50
100
Power supply required
115 Volts, 60 Hz
Maximum water
temperature
104°F (40°C)
Individual branch circuit
required
15 AMP minimum
Discharge connection
1 in. NPT
Inlet connection
1 in. NPT
Water depth rating
Maximum of 25 ft.