Place the dialer on a flat level surface or mount the unit on the wall, away from 
extreme cold or heat, direct sunlight, excessive humidity and away from 
equipment that generate strong magnetic fields. Avoid placing near large metal 
objects and areas that produce smoke, dust and mechanical vibrations. 
 

 

Clean the housing with a soft cloth lightly moistened with water or mild detergent 
solution. Never use solvents such as alcohol or thinner. Do not allow liquids to 
spill into the unit. 
 
 

The 3-Volt Lithium battery (Sanyo CR2450, Renata CR2450N or equivalent) 
are pre-installed with your WPT-900 Transmitter. Under normal use 
transmitter battery should last 12-18 months. The transmitter battery is 
always supervised and the dialer will emit beeps if the voltage drops to 
indicate replacement. Transmitter battery should be replaced at least once a 
year. After replacing the battery press either the internal or the external 
reset button to re-initialize the transmitter and restore programming (either 
the small black button located on the back of the outside of the pendant or 
the silver colored button located on the inside of the pendant). 

 

 

To ensure continuous operation during power outages, hookup to a 12VDC 
backup battery pack is recommended. (PP-1) Available from USP/Emergency 
Caller Products. 
 

 

Do not use the dialer if a gas leak is suspected or during lightning. If liquid or a 
foreign object penetrates the unit, disconnect it immediately and contact your 
installer or other qualified technician. 
 
 
When calling us for help (858-413-0149), we will be better able to help you if… 
 

 

You have read this manual  

 

Your phone line tied to the WA-900 is working. 

 

You call from a phone that is not on the same line as the WA-900 

 

C a r e   a n d   P r e c a u t i o n s  

WARNING: DO NOT EXPOSE RECEIVER UNIT OR ITS COMPONENTS, 
INCLUDING THE HORN STROBE, TO RAIN OR MOISTURE. DO NOT OPEN 
HOUSING.

LOCATION

CARE

 

WPT-900 
TRANSMITTER 
BATTERY 

OPTIONAL 
BACKUP

 

CAUTION

 

PROBLEM

6

Summary of Contents for Wanderer Alert WA-900

Page 1: ...ANDERER ALERTTM The pendant Transmitter automatically sends a signal every seconds to the receiver dialer If the receiver doesn t hear from the pendant within an adjustable period indicating patient h...

Page 2: ...ment off then on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate radio or television Increase the separation between the equipme...

Page 3: ...ntation WA 900 Pendant Movements WA 900 placed On Near metal surfaces Cross traffic Furniture Interior and Exterior Walls Building Structures Holding the transmitter next to your body or the ground wh...

Page 4: ...system and Momentary Continuous activation Special Features The dialer will beep every 30 seconds in the Program and Test mode This is to warn the user that the dialer is not in the Operate or Off mod...

Page 5: ...e illness sufferers and others who desire the reassurance of 24 hour peace of mind Combined with the cordless WPT 900 Transmitter The WA 900 will call for help even if you are unable to reach the tele...

Page 6: ...g telephone line cord 3 WPT 900 Cordless Transmitter 4 14V AC DC adaptor with 3 5mm plug 5 WPT 900 Transmitter Locking Band Not Shown 6 Wanderer Alert Unit 7 Instructional Pack Quick Start Guide Range...

Page 7: ...ery press either the internal or the external reset button to re initialize the transmitter and restore programming either the small black button located on the back of the outside of the pendant or t...

Page 8: ...VOICE VERIFICATION OGM AND 2 WAY SPEAKER FOR PLAYBACK MODE PROGRAM RECORD VOICE PAUSE DIGIT 2S DIGIT OPERATE OFF TEST MICROPHONE TO RECORD VOICE MESSAGE EASY TOUCH KEYPAD EASY PROGRAMMING WITH M 0 P...

Page 9: ...I n s t a l l a t i o n H o o k u p 8 Important This configuration should only be setup by a professional technician that has electrical wiring experience...

Page 10: ...ss the internal reset button to reset the transmitter to its most recent programming 5 Replace back cover and carefully re tighten screws evenly for tight seal 6 Thoroughly test the unit before return...

Page 11: ...be input in each phone pager location The P Pause Button Press this key to program in a pause Each P provides a 2 second pause Pauses are mainly used to compensate for connection lags such as when ca...

Page 12: ...plained in step 3B cellular phone numer explained in step 3B or a voice pager explained in step 3C VERY IMPORTANT When programming in the first number whether it is a pager or not it s necessary to pr...

Page 13: ...numbers first press 1 followed by the area code and then the number For CELLPHONES enter 3 pauses press P button 3 times after the digits of the phone number but before pressing the asterisk to recor...

Page 14: ...get an outside line with the PBX feature activated or if your phone system requires more than one digit to get an outside line it will be necessary to disable the PBX feature and instead program in t...

Page 15: ...2 NO B Press 1 to program your OGM Press 2 if you have already recorded your voice message or if you are only calling numeric pagers that don t require a voice message STEP 3 After selecting your opt...

Page 16: ...ther because of an out of range transmitter or a trigger on the hard wired input it will remain in alarm until the unit calls all programmed phone numbers or the unit is manually reset even if the tra...

Page 17: ...vered Press 2 to scroll to the next section STEP 5 To test the operation of your entire system set Mode to OPERATE and proceed as explained in the next section Operating Your System NOTE IN ORDER TO T...

Page 18: ...or High volume setting All programming information will be retained Input Activation The receiver dialer goes into alarm when either the check in signals from the pendant transmitter are not received...

Page 19: ...er dialer into the OFF mode and move the volume switch on the horn strobe to the off position Check in signals are transmitted every 10 seconds and are indicated by the blinking transmit LED When the...

Page 20: ...ROGRAM OGM prompt STEP 7 Using a prepared script and speaking six to eight inches from the dialer s microphone on the front of the unit press R when you are ready to enunciate your emergency message S...

Page 21: ...__ Week 34 ___________ Week 8 ___________ Week 35 ___________ Week 9 ___________ Week 36 ___________ Week 10 ___________ Week 37 ___________ Week 11 ___________ Week 38 ___________ Week 12 ___________...

Page 22: ...ge without notice Dialer Accessories S p e c i f i c a t i o n s Power Source PB12P AC DC Adaptor With Power Pack Rechargeable Plugs into regular 110VAC outlet to provide primary and backup power AC 2...

Reviews: