6.  Limited Warranty 

Ushio America Inc. warrants the Midori

 

UDC Portable Spot Cure LED Light Source

when new, to be free of defects in material and workmanship and to perform in  

accordance with the manufacturer’s specifications when subject to normal use and  

service for a period of 1 year from the date of purchase from Ushio America or an  

authorized agent. Ushio America will either repair or replace any components found to be 

defective or at variance from the manufacturer’s specifications within this time at no cost 

to the customer. It shall be the purchaser’s responsibility to return the instrument to the 

authorized distributor, agent, or service representative.

All non-warranty repairs will be warranted to be free from defects in materials and  

workmanship for a period of ninety (90) days from the date of the invoice.

This limited warranty does not cover the breakage or failure due to tampering,  

misuse, neglect, accidents, improper installation, modification, shipping, or to improper  

maintenance, service, fluid invasion and cleaning procedures. This limited 

 

warranty is also void if the instrument is not used in accordance with the manufacturer’s  

recommendations or if required service is performed by anyone other than Ushio  

America or an authorized agent. The purchase date determines limited warranty  

requirements. No other express or implied limited warranty is given. Suitability for use 

of the device for any procedure shall be determined by the user. Ushio America Inc. shall 

not be liable for incidental or consequential damages of any kind.

7.  Agency Approvals

The 

UDC PSC

 unit has been tested to, and found in conformance with, the following standards:

EN50581:2012
2006/95/EC (93/68 EEC) – Low Voltage Directive
IEC 62471:2006 LED Photobiological safety lamp standard, categorized as 

Risk Group 3 (High Risk).

2011/65/EU – RoHS Directive

WEEE

8.  Manufacture Contact Information

Manufactured and Serviced by:
Ushio America, Inc. 

5440 Cerritos Ave. 

Cypress, CA 90630 USA 

Tel: +1.714.236.8600

Fax: +1.714.229.3180

Toll-Free: +1.800.838.7446

[email protected]

www.ushio.com

Summary of Contents for 9500037

Page 1: ...OPERATING MANUAL UDC PORTABLE SPOT CURE LED LIGHT SOURCE...

Page 2: ...y 15 8 Manufacture Contact Information 15 Table of Contents Thank you for purchasing the Midori UDC Portable Spot Cure series LED Light Source utilizing solid state UV technology The UDC UV spot cure...

Page 3: ...Descriptions Warnings and Precautions Please be sure to handle UDC PSC unit with care at all times The electrical and optical components may be damaged by physical trauma extreme temperatures or fluid...

Page 4: ...adequate ventilation to prevent overheating DO NOT IMMERSE or store liquids above or on the UDC PSC unit Any changes or modifications made to this UDC PSC that are not expressly approved by manufactur...

Page 5: ...g momentary button next to this symbol turns on the unit for 4 seconds preset duration Pressing momentary button next to this symbol turns on the unit for 8 seconds preset duration Battery Hatch Door...

Page 6: ...anical Dimensions 27 5 1 08 73 7 2 90 46 0 1 81 Typical Spectrum Wavelength nm 250 0 20 40 60 80 100 275 300 325 350 375 400 425 450 475 500 525 550 365nm 405nm REF Relative Normalized Output Nominal...

Page 7: ...Rechargeable Battery 5002491 UPC 02 2 Bay Smart Charger for RCR123A 5002532 UPS 04 AC Main Adapter Product Ordering Information Order Code 9500037 UDC365 Spot Cure Pak Basic Kit Configuration QTY Item...

Page 8: ...o the unit using the battery symbol orientation as a guide The negative terminal of each battery should be in contact with the spring on each circuit board refer to figure 3 Attach the hatch door then...

Page 9: ...buttons refer to figure 5 and 6 WARNING Upon power up the UDC PSC operates the LED to full intensity Avoid looking directly at the LED when turning ON 2 Pressing any button while the UV output is on t...

Page 10: ...fully charged and ready for use 4 When battery has been fully charged pull the battery out of the charger and unplug the AC adapter from the charger WARNING USE ONLY APPROVED BATTERIES Use only pairs...

Page 11: ...05V 2CH 250 50mA 2CH CV 3 7V 150mV CC 200mA 2 50V 4 55V 2CH LED alter Current When the battery is fully charged LED turns red to green and the current at that time called LED alter Current 70 30mA 2CH...

Page 12: ...OT operate the charger when the temperature is higher than 40 C We recommend operating when the temperature is lower than 35 C Batteries may get warm during charging USE ONLY Tenergy Battery 30201 DO...

Page 13: ...that the battery hatch door is fully tightened on the O ring seal to prevent liquid intrusion into the battery compartment Never use any organic solvents to clean the UDC PSC unit other than isopropy...

Page 14: ...ch Make sure both batteries are the same type and freshly charged UDC UV Light Output Flashing Battery charge is low Replace batteries with freshly charged batteries This is normal behavior indicator...

Page 15: ...ct accidents improper installation modification shipping or to improper maintenance service fluid invasion and cleaning procedures This limited warranty is also void if the instrument is not used in a...

Page 16: ...022019 UDC UV 5440 Cerritos Avenue Cypress CA 90630 TEL 714 236 8600 FAX 714 229 3180 www ushio com MADE IN USA...

Reviews: