SEED CONDITIONER
Problem
Possible Cause
Solution
When control panel power switch
is turned on, panel has no
power .
1. If wired to a plug, plug not
fully engaged in outlet.
2. Power source panel circuit
breaker tripped.
1. Seat plug in outlet.
2. Re-set panel breaker.
A Fan or the belt will not start .
1. Blown fuse.
2. Over current fault.
1. Replace fuse.
2. Power system down, wait ten
seconds then turn power on
to reset VFD’s.
System has power but will not
start .
1. E-Stop switch engaged
2. Fans and belt in OFF mode
on the HOA screen
1. Pull out E-Stop switch and
press E-Stop reset button.
2. Place Fans and belt in the
ON mode.
System not start when attached
to a treater.
1. Auxiliary cable not attached
to treater.
2. Fans and belt are not in
AUTO mode on the HOA
1. Attach auxiliary cable to
treater.
2. Place Fans and belt in the
AUTO mode.
Excessive wire mesh belt noise.
1. Belt is not aligned and
tracking properly.
1. Align belt and adjust tracking
(see page 31).
Wire mesh belt is slipping.
1. Not enough tension on the
belt.
1. Increase belt tension
(see page 30).
Seed not leveling in bed.
1. Not enough air cylinder
pressure on seed leveling
gate.
1. Increase the air pressure on
the pneumatic regulator.
TROUBLESHOOTING
Below is a table describing the most frequent problems and solutions with the USC
Seed Conditioner . For further assistance, contact the USC Service department at
(785) 431-7900.
Troubleshooting
Section
E