20
Visit us online at www.USWaterSystems.com Give us a call at: 1-800-608-8792
Backwash Frequency
Programming Instructions
TIME OF DAY, YEAR, MONTH, DAY,
Time of day is for normal operation of system and the scheduling of the re-
generation time. The date is used in a diagnostic function to track the last
time the system regenerated.
REGEN DAYS
This value is the number of days between regenerations or back washes to
clean the filters.
GALLONS
Default value is OFF. This should not be changed.
REGEN TIME
This setting determines the time of day to perform a scheduled regenera-
tion. The normal regen time for a filter is 12:00 AM.
Settings
Press SETINGS key (3 SECONDS / BEEP)
VALVE MODE
B.W. FILTER
TIME OF DAY
12:01 PM
YEAR
2012
MONTH
AUGUST
DAY
21
REGEN DAYS
3 DAYS
GALLONS
OFF
REGEN TIME
12:00 AM
PROGRAMMING
COMPLETE
Contact US Water Systems at 1-800-608-8792 to help with the backwash frequency setting.
This can be adjusted by the home owner to suite their individual needs with frequencies
available from 1 – 99 days. The system default will be 3 days. Typically on municipal
sources can be extended to 7 days.