background image

 

 

 

3

 

System  Overview  and  Specifications

 

 

US  Water  has  pioneered  the  use  of  hydrogen  peroxide  in  water  treatment  for  the  eradication  of  
iron  (rust),  sulfur  (hydrogen  sulfide  odor)  and  manganese  for  nearly  20  years.  It  can  truly  be  
called  an  "Eradication  System"  because  it  TOTALLY  removes  iron,  sulfur  and  manganese.  
Properly  sized,  an  Oxi

-

Gen  Hydrogen  Peroxide  System  from  US  WATER  is  THE  MOST  

EFFECTIVE  METHOD  for  removing  iron,  rust,  sulfur,  hydrogen  sulfide  and  manganese  and  the  
rotten

-

egg  odor  from  your  water  supply.  Hydrogen  Peroxide  is  not  a  hazardous  chemical  

-

  to  

the  contrary,  hydrogen  peroxide  (H2O2)  is  composed  of  the  elements  of  water:  Hydrogen  and  
Oxygen.  There  is  nothing  foreign  or  chemical  added  to  the  water  supply.  Unlike  chlorine,  
hydrogen  peroxide  requires  no  contact  time  and  the  reaction  (oxidation  of  iron,  rust,  sulfur,  
manganese  and  hydrogen  sulfide)  is  immediate.  The  Oxi

-

Gen  Hydrogen  Peroxide  System  is  

the  answer  to  practically  any  iron,  rust,  sulfur,  hydrogen  sulfide  and  manganese  problem,  and  
is  backed  with  our  90

-

Day  100%  Satisfaction  Guarantee.  US  Water  Systems  guarantees  100%  

iron,  manganese  and  sulfur  removal  with  its  Oxi

-

Gen  System  which  utilizes  Hydrogen  Peroxide  

or  H2O2.

 

  

 

 

Sizing  is  based  upon  number  of  bathrooms

 

1  Bathroom  

-

  5  GPM

 

2  Bathrooms  

-

  8  GPM

 

3  Bathrooms  

-

  10  GPM

 

4  Bathrooms  

-

  12  GPM

 

5  Bathrooms  

-

  15  GPM

 

 

 

 

 

 
 

Hydrogen  peroxide  or  H2O2  is  a  powerful,  yet  versatile  oxidant  that  is  both  safe  and  effective.  
Consider  the  H2O2  advantages  and  you’ll  know  why  this  is  the  ONLY  sure  way  to  eradicate  
iron,  manganese  and  sulfur.

 

Powerful

 -

  H2O2  is  one  of  the  most  powerful  oxidizers  known  and  is  much  stronger  than  

chlorine,  chlorine  dioxide,  and  potassium  permanganate.

 

Safe

 -

  H2O2  is  formed  by  the  action  of  sunlight  on  water  and  is  a  natural  purification  system  for  

our  environment.  Consequently,  H2O2  has  none  of  the  problems  of  gaseous  release  or  
chemical  byproducts  that  are  associated  with  other  chemical  oxidants.  And  since  H2O2  is  
totally  miscible  with  water,  it  reverts  back  to  hydrogen  and  oxygen  after  the  reaction  is  
complete.

 

Versatile

 -

  Hydrogen  Peroxide  is  lethal  to  iron,  sulfur  and  manganese.  PERIOD!

 

Selective

 -

  In  itself,  H2O2  is  a  fantastic  oxidizer,  much  better  than  chlorine  and  potassium  

permanganate.  It  poses  no  health  hazard  and  ERADICATES  100%  OF  THE  IRON,  SULFUR  
OR  MANGANESE  –  ALL  THE  TIME  –  GUARANTEED!

 

Consult  one  of  water  specialists  for  higher  flow  rates.  US  Water  offers  OXi  systems  up  to  100  
GPM  and  can  custom  design  them  at  no  extra  charge.  Call  us  at  800

-

608

-

USWA  or  e

-

mail  us  

at  [email protected]  .

   

Installation,  Operation  and  Maintenance  Manual

 

Matrixx  Oxi

-

Gen  MO

-

1,  MO

-

2,  MO

-

3,  MO

-

4,  System

 

Summary of Contents for Oxi-Gen 150-MO-1

Page 1: ... Matrixx Oxi Gen Iron Sulfur and Manganese Eradication System Oxi Gen 150 MO 1 Oxi Gen 150 MO 2 Oxi Gen 150 MO 3 Oxi Gen 150 MO 4 US Water Systems Inc 1209 Country Club Road Indianapolis IN 46234 1 800 608 8792 info uswatersystems com www uswatersystems com ...

Page 2: ...6 Carbon Filter Media and Valve Installation 8 Injection System Installation Continued 9 Carbon Filter Installation 10 Carbon Filter Valve Features and Programming 11 System Startup 12 What To Expect and Routine Maintenance 13 Maintenance Schedule 14 System Flow Schematics 15 16 Programming Chart 17 Warranty 18 Installation Operation and Maintenance Manual Matrixx Oxi Gen MO 1 MO 2 MO 3 MO 4 Syste...

Page 3: ...n number of bathrooms 1 Bathroom 5 GPM 2 Bathrooms 8 GPM 3 Bathrooms 10 GPM 4 Bathrooms 12 GPM 5 Bathrooms 15 GPM Hydrogen peroxide or H2O2 is a powerful yet versatile oxidant that is both safe and effective Consider the H2O2 advantages and you ll know why this is the ONLY sure way to eradicate iron manganese and sulfur Powerful H2O2 is one of the most powerful oxidizers known and is much stronger...

Page 4: ...taminants and the by product is H2O water This is much safer than using chlorine in that chlorine can cause other problems in the water stream such as chloramines and trihalomethanes THM s Once the water has been injected with hydrogen peroxide it passes through the backwashing carbon filter The backwashing carbon filter uses catalytic carbon to act as a catalysis to remove the oxidized contaminan...

Page 5: ... from a dry contact flow switch the pump will run at the selected speed when the switch is closed and stop when the switch opens 24 VAC Input The pump will run at the selected speed when it nreceives a 24 VAC signal from a water softener or other equipment Econ FP is ideal for light duty water conditioning applications Up to 30 gpd 80 psi Wall mountable Adjustable from 10 to 100 Patented quick rel...

Page 6: ... A D pages 12 to 13 Program Pump for SECONDS mode water meter steps 1 4 pages 14 to 15 24 VAC AUXILIARY The pump will accept a 24 VAC signal from a water softener or other type of control equipment that responds to flow and will run at a set speed for as long as it receives the 24 VAC signal The connection is not polarity sensitive polarity is not an issue when connecting the auxiliary wires Instr...

Page 7: ...own arrows are used in conjunction with the button to change MODE the mode of operation The arrows are also used in conjunction with the button to adjust the pump operating time percentage for the 1 5 10 20 OR 60 SECONDS mode water meter or the pump speed setting for the FLOW SWITCH and AUXILIARY operational modes CONTROL PANEL GUIDE INDICATORS The display has four flashing indicators beneath the ...

Page 8: ...ia 5 Use the Funnel provided to pour the media into the tanks Pour it evenly around the hole to ensure it is well distributed in the tank and pour slow enough to keep from plug ging the hole Evenly divide the gravel and carbon and pour in the tanks Important It is a good practice to hold a shop vac close to the funnel to collect any dust that escapes during the filling process Safety glasses and a...

Page 9: ...rbon filter outlet to the existing equipment or to the house plumbing if no additional equipment is required Be sure all solder joints within 18 of the plastic connections are made prior to con necting to the plastic components see carbon filter installation for proper connection to the carbon filter 9 Now install the injector in the injection tee Be sure to use Teflon tape to seal the threads on ...

Page 10: ...for residential drain line should be a minimum of 1 2 Backwash flow rates in excess of 7 gpm or length in excess of 20 re quire 3 4 drain line Commercial drain lines should be the same size as the drain line flow control 4 The inlet on the bypass valve is indicated by an arrow that will point toward the valve The outlet will be indicated by an arrow pointing away from the valve 5 Solder joints nea...

Page 11: ...alue Now press the down arrow to move to the next parameter 6 The next parameter is Regen Days This is the amount of days between backwashes This is factory set to 3 You can use the table on page 4 as a guideline for proper frequency This is only a guideline and ac tual backwash frequency could vary Typically the values on the table will work for 90 of all applications To change this value press a...

Page 12: ...pen the kitchen sink faucet and pull a sample of the water The sample should be full of air bubbles that come to top and dissipate over 1 2 minutes 9 Adjust the pump higher than 50 if necessary until the sample is full of bubbles The pump can be adjusted by holding the button and using the up or down arrows 10 Once there is a sample full of air bubbles from the kitchen sink faucet start to adjust ...

Page 13: ...may be bubbles in the water for a few weeks after installation A few bubbles are fine but if there is fizz that remains for several seconds it is an indication that the system is being overfed with H2O2 This occurs because after installation the water will become cleaner and the initial dosage of H2O2 may need to be adjusted to compensate for the low er contaminant level Routine Maintenance Pressu...

Page 14: ... 5 Years 411 EC30G 2 Injection Panel Duck Bill Check Valve Replace injection check valve as needed 1 5 Years 411 UCCVDBO H2O2 Solution Tank Periodically check the solution level and refill as needed Varies by wa ter usage 710 HP22N Carbon Tank Check the clock and settings periodically or after a power outage 4 Months N A Installation Operation and Maintenance Manual Matrixx Oxi Gen MO 1 MO 2 MO 3 ...

Page 15: ...15 Flow Schematic Single Tank System Installation Operation and Maintenance Manual Matrixx Oxi Gen MO 1 MO 2 MO 3 MO 4 System ...

Page 16: ...16 Flow Schematic Dual Tank System Installation Operation and Maintenance Manual Matrixx Oxi Gen MO 1 MO 2 MO 3 MO 4 System ...

Page 17: ...17 Programming Chart Installation Operation and Maintenance Manual Matrixx Oxi Gen MO 1 MO 2 MO 3 MO 4 System ...

Page 18: ...aused by iron sulfur bacterial iron silt sand tannins or ganics bacteria hot water or chlorine voids the warranty on resin These warranties are in lieu of all other warranties expressed or implied and we do not authorize any person to assume for us any other obligation on the sale of this water conditioner No responsibil ity is assumed for delays or failure to meet these warranties caused by strik...

Page 19: ...ase can be Wghtened by hand as per Figure C or with the opWonal wrench and mulW adaptor as per Figure D Install Tank Base into Tank Thread Figure C Tighten by hand Figure D Op onal ghten by wrench and mul Tadaptor SECTION E 1 Install the clamp ring over the valve threads onto the valve as per Figure E and F Install Clamp Ring onto Valve Thread Figure E Valve threads before clamp ring installed Fig...

Page 20: ...ector SECTION N HTO SoWener Valve Programming Page 2 SECTION H AVach Valve to Tank Base Figure J Insert valve into tank base Figure K Clamp ring installed and ghtened 1T2 turns 1 Insert the valve into the tank base as shown in figure J Insure the o ring is in proper locaWon before inserWng FAILURE TO FOLLOW THIS STEP CAN PINCH AND DAMAGE THE OTRING WHICH MAY RESULT IN A LEAK AND VOID THE PRODUCT WA...

Reviews: